During an image pasting exam, the system completes the first exposure, moves to the second position, and then…
Definium 8000 Thunder
Symptom
During an image pasting exam, the system completes the first exposure, moves to the second position, and then aborts with errors See Long Descripton for errors and Atttachments for screen images During an image pasting exam, the system completes the first exposure, moves to the second position, and then aborts with the following errors: 1453,2009-02-10,11:47:55:202,"VEN",5000051, AFRF has detected fault in the system,2222,DO,DEFAULT, SysCntrl, SysCntrl, Software_Problem,2,1,1, Component DetectionObjectImpl has been classified as Severity 2. Restarting the component with notification to Fault Notification Consumers.,../subsysmgr/subsysmgr/FaultRecovery.cpp,433 1454,2009-02-10,11:47:55:224,"VEN",5000051, AFRF has detected fault in the system,2222,DO,DEFAULT, SysCntrl, SysCntrl, Software_Problem,2,1,1, Component SensorObjectImpl has been classified as Severity 2. Restarting the component with notification to Fault Notification Consumers.,../subsysmgr/subsysmgr/FaultRecovery.cpp,433 1455,2009-02-10,11:48:00:260,"VEN",200049, Acquisition ended before all exposures completed,2222,WR,DEFAULT, SysCntrl, control, Cancelled Acquisition,1,1,1, EXPOSURE_ABORTED event while in EXECUTE_START_SEQ,XRAcqSyncSM.cpp,275 1456,2009-02-10,11:48:00:542,"VEN",1600140, Aborting Image Processing for the specified frame ,2222,DO,DEFAULT, XRImProc, Constructor, 1. Retry the operation 2. Reset the operation and try again. 3. Call service if problem persists.,1,0,1, Aborting Sequence : 2,XRImProc.cpp,3965 A "software failure" message box pops up on the left monitor and no images are displayed in the right monitor - see the pictures below.. After a reset, the users cannot find the image taken. They then repeat the exam and everything works OK.
Applies to
- Models
- Definium
- Product
- Definium 8000
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- AEC Backup Time message
- Definium 8000 Auto positioning does not work after a reset/reboot due to wall stand receptor at a hard limit during rebooting or repowering.
- Definium 8000 One or both monitors display the following message on every boot
- Definium 8000 Wallstand or Table Only Configurations running VolumeRAD M3 Software.
- Definium 8000 OTS Collimator has no power due to a tripped breaker (CB8) ont he Tube Suspension Logic (TSL) Board.
- Definium 8000 The Siemens Collimator has not power due to a tripped breaker (CB9) on the Tube Suspension Logic (TSL) Board.