Pular para o conteúdo principal
GE Healthcare · MRDiscovery22246662268843

Troubleshooting Information Needed for Inability to Scan or Scan Interruptions due to Error, Gradient coil IBC inlet tem…

Troubleshooting Information Needed for Inability to Scan or Scan Interruptions due to Error, Gradient coil IBC inlet temperature delta sensor trip.

Symptom

Troubleshooting Information Needed for Inability to Scan or Scan Interruptions due to Error, Gradient coil IBC inlet temperature delta sensor trip See Long Description Unable to scan due to the errors shown below. Or, the errors shown below are interrupting scans. How do we troubleshoot this problem? 2268843 CMR3T NSP SCP:SriCanHWO 2030 Exception Class: Unknown Severity: UnknownFunction: Patient Handling: Control/DisplayPSD: FSE-XL Coil: 8US TORSOPA Scan: 15/7 Gradient coil IBC inlet temperature delta is above the warning limit.Future scanning will be inhibited, until temperatures are back in range.Temperature Delta: 3 degrees CWarning Limit: 3 degrees C-> 2224666 CMR3T psc ../PscMainControl.cc 1375 Exception Class: UnknownFunction: Prescan: Host Autoprescan Auto Prescan failed, Gradient coil IBC inlet temperature delta sensor trip

Error message

2224666 Auto Prescan failed, Gradient coil IBC inlet temperature delta sensor trip See Long Description 2224666 CMR3T psc ../PscMainControl.cc 1375 Exception Class: Unknown Function: Prescan: Host Autoprescan Auto Prescan failed, Gradient coil IBC inlet temperature delta sensor trip

2268843 Gradient coil IBC inlet temperature delta is above the warning limit. Future scanning will be inhibited, until temperatures are back in range. See Long Description 2268843 CMR3T NSP SCP:SriCanHWO 2030 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Control/Display PSD: FSE-XL Coil: 8US TORSOPA Scan: 15/7 Gradient coil IBC inlet temperature delta is above the warning limit. Future scanning will be inhibited, until temperatures are back in range. Temperature Delta: 3 degrees C Warning Limit: 3 degrees C-> Extended Error : The gradient coil has inner bore coolant (IBC) temperature sensors these sensors are on the outside of the gradient coil and are intended to measure the temperature of the coolant in the coil. A difference between these readings indicates that the coolant flow is likely blocked in the gradient coil or in the manifold.

Applies to

Models
Discovery
Product
Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
Software
20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.