Wallstand Image Detector Calibration Data Upload Error displayed on the left monitor at boot up
Symptom
Wallstand Image Detector Calibration Data Upload Error displayed on the left monitor at boot up See Long Description for Details After a load from cold of the VolumeRAD M4 software and a restore of backups, a message "Wallstand image detector calibration data upload error..." is displayed on the left monitor screen after every boot. The following errors may be reported in the System Error Log: 2009-03-03,08:52:36:164,"VEN",1210706, (ERROR),2222,WR,DEFAULT, (ERROR), (ERROR), (ERROR),1,0,1, Correction Error - Cal File Not Found,ImDetEventHandler.cpp,666 2009-03-03,08:52:36:577,"VEN",1211101, (ERROR),2222,WR,DEFAULT, (ERROR), (ERROR), (ERROR),1,0,1, Detector calibration data upload in progress,ImDetEventHandler.cpp,666 2009-03-03,08:52:37:320,"VEN",1211103, (ERROR),2222,WR,DEFAULT, (ERROR), (ERROR), (ERROR),1,0,1, Detector calibration data upload done failed,ImDetEventHandler.cpp,666 (error code text is wrong - 1211102 is upload done) In Service Desktop > Utilities > Detector Data Download > Wallstand Detector Data Download, the Current Version field is blank. A download of the Firmware and/or Calibration Data, even though successful, will not resolve this problem.
Error message
Entries in the System Error Log: 1210706 1211101 1211103 See Long Description for Details 2009-03-03,08:52:36:164,"VEN",1210706, (ERROR),2222,WR,DEFAULT, (ERROR), (ERROR), (ERROR),1,0,1, Correction Error - Cal File Not Found,ImDetEventHandler.cpp,666 2009-03-03,08:52:36:577,"VEN",1211101, (ERROR),2222,WR,DEFAULT, (ERROR), (ERROR), (ERROR),1,0,1, Detector calibration data upload in progress,ImDetEventHandler.cpp,666 2009-03-03,08:52:37:320,"VEN",1211103, (ERROR),2222,WR,DEFAULT, (ERROR), (ERROR), (ERROR),1,0,1, Detector calibration data upload done failed,ImDetEventHandler.cpp,666 (error code text is wrong - 1211102 is upload done)
Applies to
- Models
- Definium
- Product
- Definium 8000
- Software
- Volume Rad M4
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- AEC Backup Time message
- Definium 8000 Auto positioning does not work after a reset/reboot due to wall stand receptor at a hard limit during rebooting or repowering.
- Definium 8000 One or both monitors display the following message on every boot
- Definium 8000 Wallstand or Table Only Configurations running VolumeRAD M3 Software.
- Definium 8000 OTS Collimator has no power due to a tripped breaker (CB8) ont he Tube Suspension Logic (TSL) Board.
- Definium 8000 The Siemens Collimator has not power due to a tripped breaker (CB9) on the Tube Suspension Logic (TSL) Board.