GE Healthcare · CTDiscoveryVCT2300230901456737988350405
Maximum azimuth view ratio error Message Is Posted during a tube warm-up
Symptom
Maximum azimuth view ratio error Message Is Posted during a tube warm-up See Long Description Maximum azimuth view ratio error Message is posted during a tube warm-up. This message is posted during a tube warm-up. Host: PROSCT01 Process: dailyPrepRx File: DailyPrepUtils.c Line: 1254 QUALITY CONTROL SCANS Exam: 50169 Series: 1 Scan: 4 Maximum azimuth view ratio error: 7063.285645
Error message
Error : 230023090 - Maximum azimuth view ratio: xxxxx.xxx See Long Description for more information. 230023090 - Maximum azimuth view ratio: 14567.379883 Sun Jan 9 10:24:56 2011 Error: 230023090 Host: uvaradct03 Process: dailyPrepRx File: DailyPrepUtils.c Line: 1392 QUALITY CONTROL SCANS Exam: 50405 Series: 1 Scan: 4 Maximum azimuth view ratio: xxxxx.xxxxx
Applies to
- Models
- Discovery, VCT
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 08MW39.4 for Discovery CT750 HD 08MW39.4 for Discovery CT750 HD 11/17/2008 Inital M3 release. 08MW39.4 for Discovery CT750 HD 11/17/2008 Inital M3 release. - Discovery CT750 HD Collector 5323588 Rev 3 includes OS and Application CD's - Operating System Linux 5.3.8 Software CD 5323584 Rev 1 - Application CT750 HD DVD 5323585 Rev 3 ======================================================= - Class C CT750 5233586 Rev 1 - Class M CT750 5323587 Rev 1 An On-site / Remote identification aid . (Example: check_config) Result from check_config or swhwinfo: 08MW39.4.V40_PS_HD64_G_GTM 08MW39.4.V40_PS_HD64_G_GTL
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required