GE Healthcare · CT
Lightspeed 1.X - Octane
Symptom
System with Octane fails to boot. As soon as it's turned on there is no display and the monitors go into power saving mode.
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2169940-45 IP-30 used on Octane I Computer See LD for more info 2169940-45 IP-30 used on Octane I Computer Part #: 2169940-45 Part Type: GP REPAIRABLES Part Weight: 1.81 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: PCA REV F HEART IP30 SYSTEM BOARD FRU: Yes Status: Orderable Comments: FLS - PCA REV F HEART IP30 SYSTEM BDU/O HELIOS & CTI FOR CTI SYSTEMS MUST HAVE 6.1 SOFTWARE SCHEDULED FOR RELEASE FW 29 2000 PER PCN 199811 MS08992 6/27/00 MS5500 6/21/01 SGI NUMBER 030-1467-001. CHECKLABEL ON BOARD TO DETERMINE YOUR BOARD TYPE. IF BOARD BEING REPLACED IS LABELED 030-0887-005 ORDER THE T3202KT !!!! IF SYSTEM CAN BE BROUGHT UP TOCOMMAND MONITOR, THE SYSTEM COMMAND WILL LIST IP30 BOARD TYPE. IF SYSTEM CAN BE BROUGHT UP TOIRIX, THE HINV -M COMMAND WILL LIST IP30 BOARD TYPE. PLEASE ORDER THE CORRECT TYPE OF BOARD TO PREVENT COMPATIBILITY ISSUES AND INCREASED COSTS. GELS - "PCA REV F HEART IP30 SYSTEM BD U/O HELIOS & CTI PCN 199575 BACKWARD COMPATIBLE WITH 2169940-13 (ALL GONE') SEE D91SOURCE: SGI-BROOKFLIED, WI (SILICON GRAPHICS, INC.) MS08992 8/25/99",IP 30 BD Note: Octane 1 has two ESI Graphics boards ct01 10# hinv -mv Location: /hw/node PM20300MHZ Board: barcode LLJ521 part 030-1356-001 rev N Location: /hw/node/xtalk/15 IP30 Board: barcode LKF767 part 030-1467-001 rev D Location: /hw/node/xtalk/15/pci/2 FP1 Board: barcode MCC875 part 030-0891-003 rev H PWR.SPPLY.ER Board: barcode AAE1060336 part 060-0035-002 rev A Location: /hw/node/xtalk/13 XTALKPCI Board: barcode LKV989 part 030-0952-005 rev E Location: /hw/node/xtalk/13/pci/3 PCI_ENET Board: barcode KZM587 part 030-1155-002 rev D Location: /hw/node/xtalk/12 MOT10 Board: barcode LDX145 part 030-1241-002 rev K Location: /hw/node/xtalk/11 MOT10 Board: barcode LKJ740 part 030-1241-002 rev K 2 300 MHZ IP30 Processors Heart ASIC: Revision F CPU: MIPS R12000 Processor Chip Revision: 2.4 FPU: MIPS R12010 Floating Point Chip Revision: 0.0 Main memory size: 1536 Mbytes Xbow ASIC: Revision 1.4 Instruction cache size: 32 Kbytes Data cache size: 32 Kbytes Secondary unified instruction/data cache size: 2 Mbytes Integral SCSI controller 0: Version QL1040B (rev. 2), single ended Disk drive: unit 1 on SCSI controller 0 (unit 1) Disk drive: unit 2 on SCSI controller 0 (unit 2) Integral SCSI controller 1: Version QL1040B (rev. 2), single ended Optical disk: unit 3 on SCSI controller 1 CDROM: unit 6 on SCSI controller 1 Integral SCSI controller 2: Version QL1040B (rev. 2), single ended Disk drive: unit 1 on SCSI controller 2 (unit 1) IOC3 serial port: tty1 IOC3 serial port: tty2 IOC3 parallel port: plp1 Graphics board: ESI with texture option Graphics board: ESI Integral Fast Ethernet: ef0, version 1, pci 2 Fast Ethernet: ef1, version 1, pci 3 Iris Audio Processor: version RAD revision 12.0, number 1 PCI Adapter ID (vendor 4265, device 3) pci slot 2 PCI Adapter ID (vendor 4215, device 4128) pci slot 0 PCI Adapter ID (vendor 4215, device 4128) pci slot 1 PCI Adapter ID (vendor 4265, device 5) pci slot 3 PCI Adapter ID (vendor 4215, device 4128) pci slot 1 PCI Adapter ID (vendor 4431, device 40) pci slot 2 PCI Adapter ID (vendor 4265, device 3) pci slot 3 PCI card, bus 0, slot 2, Vendor 0x114f, Device 0x4
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required