Symptom
Monitor has a line or other artifact that is not part of the image. If the image is moved or resized the artifact does not move with it. See Short description Monitor has a line or other artifact that is not part of the image. If the image is moved or resized the artifact does not move with it.
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5169069 19 INCHES COLOR MONITOR LCD 1990SXi. See long description for details Part #: 5169069 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 2.43 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: OEM 19 INCHES COLOR MONITOR LCD 1990SXi - SILVER FRU: Yes Status: Orderable Comments: Check graphics board output connector: if 13W3M you need to order 13W3M/HD15 adaptor: 2261178. Per eNPI Project 015197, 212008898, 11/10/06. This monitor should not be ordered for use on 11.X, 10.X, 9.X, or 8.X Signa MR systems until further notice. Required monitor gamma table is not yet available for these systems. Instead order 5117545. (212002950 - 4/25/2007)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required