GE Healthcare · Nuclear MedicineMillennium
When MG activated to move to cardiac mode, radius move to 251 and stops, then gives error radial not in position for car…
When MG activated to move to cardiac mode, radius move to 251 and stops, then gives error radial not in position for cardiac mode.
Symptom
When MG activated to move to cardiac mode, radius move to 251 and stops, then gives error radial not in position for cardiac mode. The error that pops up on the screen is: ERROR_RADIAL_NOT_OK(48) reported on VG axis
Error message
ERROR_RADIAL_NOT_OK (48) reported on VG axis ERROR_RADIAL_NOT_OK (48) reported on VG axiss This is what was in the error log, in case it might help. genieacq:TGC_PH:120:motion.c[revision:1.60.2.4$] mot_try_to_start( ) line 1293 error 0x4300004 level 2 "execute CARDIAC_GEOMETRY' motion genieacq: gip_ph:43:gip_util.c[$revision:1.49.2.2$] gipVGerror ( ) line 1524 error 0x07100017 level 2 "radial 1 and/or radial 2 failed to acheive position for transition to MG mode" (GIP_E_RADIAL_NOT_OK) genieacq:TGC_PH:120:moveio.c[revision:1.11.2.60] mio_gip_r_transition ( ) line 1421 error 0x14300009 level 3 "geometry change failed with error 48" genieacq:sequtil.c[$revision 1.35.2.11$] TGC_SEQ_EVENT line 1403 error 0x14300014 level 2 "error 12 moving VG axis" CARDIAC_GEOMETRY motion stopped
Applies to
- Models
- Millennium
- Product
- MG/MC/Myosight Millennium MG/MC Millennium MyoSIGHT
- Component
- *Gantry Gantry Gantry CBL000890 MG Detector 2 cable to Inner Cable chain bracket CBL000890 MG Detector 2 cable to Inner Cable chain bracket CBL000891 MG Detector 1 cable to Outer Cable chain bracket CBL000891 MG Detector 1 cable to Outer Cable chain bracket
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Need part numbers for the Millennium MG/MC table E-Stop
- How do I Delete a file on Genieacq that the system thinks is still acquiring
- VG, the contour works... but in the opposite way.
- MG_MC_MyoSight_MPR_MPS Bar Phantom Resolution Size