GE Healthcare · CTHiSpeed18395218392128848503891265527513081394
Scanner Hardware Stopped Scan
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 183952 Gantry (Axial) LOOP CONTACTOR Error. OVERSPEED condition - Could NOT CLOSE Gantry (Axial) Loop Contactor. Axial Gantry Command/Status:0x129e00. HW Error: A RESET of the STC controller is required and try again. See Long Description for Details. Error: 183952 Gantry (Axial) LOOP CONTACTOR Error. Thu Jan 26 09:01:27 2006 Error: 183952 Suite: CT01 Host: STC Process: Axial File: ax error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Loop Contactor Interlocks Scan: 4756/3/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 09:01:24:635 Log Series: 392 Gantry (Axial) LOOP CONTACTOR Error. OVERSPEED condition - Could NOT CLOSE Gantry (Axial) Loop Contactor. Axial Gantry Command/Status:0x129e00. HW Error: A RESET of the STC controller is required and try again. Error: 183921 Axial conditions at FAULT: See Long Description for complete error Mon Oct 17 08:26:48 2005 Error: 183921 Suite: SMCT Host: STC Process: Axial File: ax_error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 28848/2/1 Type: Helical Exception Level: Pri/Most Severe Time: 08:26:47:775 Log Series: 141 Axial conditions at FAULT: velocity_fb = 266
Applies to
- Models
- HiSpeed
- Product
- HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-264806G2 AXIAL CONTROL BOARD ALLOWING .8 SEC See long description for details Part #: 46-264806G2 Part Type: GP REPAIRABLES Part Weight: 1.81 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: AXIAL CONTROL BOARD ALLOWING .8 SEC FRU: Yes Status: Orderable Comments: OBSOLETE PART case 6763061 This part has been identified as obsolete and no short-term solution has been identified FE must identify and order a higher or lower level spare part as required Contact your support engineer on-line engineer or Parts ID team should you require support 212012173 05-23-07 FLS - FE ASSIT: MS6588 05/22/98 46-264806G2 = AXIAL BD FOR CTI& QXI SYSTEMS WITH 0.8 SEC SCANNING. THIS BOARD HAS THE PALS FOR 0.8 SECOND ROTATION. THE T3202KD = .8 SEC AXIAL BD. THE T3202BD =1.0 SEC AXIAL BD. THE ONLY DIFFERENCE BETWEEN THE T3202KD AND T3202BD ARE TWO PALS. THE T3202BD CAN BE UPGRADED TO THE T3202KD BY CHANGING PALS U211 AND U101. DO YOU STILL WANT TO ORDER THIS PART?
- Area
- CT