GE Healthcare · CTHiSpeedVCT26000104911497260001012

Scanner Hardware Stopped Scan

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260001049 Communications with the DCB sub-system has not been established. Scanning aborted. See LD for complete error Wed Nov 22 07:15:07 2006 Error: 260001049 Host: OBC Process: HOP File: hop_misc.c Line: 265 Function: No System Function Reported Scan: 11497/3/1 Type: Scout Exception Level: Secondary Time: 07:15:06:725 Log Series: 94 Communications with the DCB sub-system has not been established. Scanning aborted.

Error: 260001012 The Rotating Controller Interface Bus (RCIB) fault line has been asserted See Long Description for the full error code Sat Jun 9 14:37:06 2001 Error: 260001012 Host: OBC Process: HOP File: hop_fault_state.c Line: 137 Function: No System Function Reported Scan: 9553/3/1 Type: Axial Exception Level: Pri/Most Severe Time: 14:37:06:030 Log Series: 366 The Rotating Controller Interface Bus (RCIB) fault line has been asserted. None of the sub-systems have reported a problem. Check nodes or fault line for failure.

Applies to

Models
HiSpeed, VCT
Product
HiSpeed QX/i - GRE Always MDAS 4 QX_P_M4 HiSpeed QX/i - GRE Method of visual identification Small rounded gantry similar in appearance to LS 3.X and 4.X. Always has an MDAS 4 slice Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. xxx
Component
2253562 EIGHT SLICE DAS CONTROL BOARD also used on MDAS 4 See Long Description Part #: 2253562 Part Type: GP CONSUMABLES Part Weight: -13639.86 KGM Repairable: No Returnable: No Hazardous Material: N Description: EIGHT SLICE DAS CONTROL BOARD FRU: Yes Status: Orderable ====================== Parts Offered as: Current: 2253562 Harvested: Not Available Exchange: Not Available Comments: FLS - EIGHT SLICE DAS CONTROL BOARD.USED ON WARP3. SUPPLIER IS SCI. MSA6724 EJM 05/16/01 COLLECTION OF DEFECTIVES START7/23/01 MS5277 TAKEN OFF RECYCLING PROGRAM PER L.BENIWAL (MSA8429 08/20/02) GELS - LIGHTSPEED ULTRA DCB / OPTIC FIBER FREQ 33 MHZ / NEEDS DIP BOARD REF 2259530 PDB 02/01/21 DNA FOR A REWORK TO PURGE MATERIAL FOR QUALITY ISSUE PER REQUEST O CT ENG/A REGAL 03/01/20,DAS CONTROL BOARD 2215315 DAS DCB TERMINATOR used on SDAS, MDAS, GDAS See Long Description 2215315 DAS DCB Terminator used on SDAS, MDAS, GDAS Part #: 2215315 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: DAS DCB TERMINATOR FRU: Yes Status: Orderable DAS DCB Terminator used on SDAS, MDAS, GDAS (212001261 4/9/08)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.