GE Healthcare · CTLightSpeed214343160152161616349169159

Lightspeed 1.X - Octane

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 214343 MA out of WARNING tolerance Mon Jan 26 20:19:25 2009 Error: 214343 Host: OBC Process: Diag Exec File: technic_monitor.c 1.40 Line: 1680 Function: Diagnostics XRAY GENERATION : MA Loop Test Name: XRay - Manual Unique ID: 16015 Iteration: 1 Exc. Level: Soft Time: 21616 Error Type: Hardware MA out of WARNING tolerance. Selection: 80KV 40mA MA loop=1 (0=Open 1=Closed) Tolerance: Upper=42.0mA Lower=37.9mA Total samples: 11 . Samples Aver mA . Aver mA Above Tol Above Tol below Tol Below Tol ----------------------------------------------------------------- Anode 37.5mA 0 0.0mA -- -- Function: Diagnostics XRAY GENERATION : MA Loop Test Name: XRay - Manual Unique ID: 16349 Iteration: 1 Exc. Level: Soft Time: 169159 Error Type: Hardware . Selection: 120KV 40mA MA loop=1 (0=Open 1=Closed) Tolerance: Upper=42.0mA Lower=37.9mA Total samples: 53 . Samples Aver mA . Aver mA Above Tol Above Tol below Tol Below Tol ----------------------------------------------------------------- Anode 37.3mA 0 0.0mA -- -- Cath 40.1mA 14 45.8mA 18 35.8mA

Applies to

Models
LightSpeed
Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2154834 MA Board used on (CT/i,1.X-4.X) scanners See Long Description for more Part #: 2154834 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 1.81 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MA CONTROL BRD./CANCEL FRU: Yes Status: Orderable Comments: FLS - MA BOARD USED ON FAST RHAPSODE FMI#25238 UPGRADES THIS BD. TO A REV.1 ONE USE LIGHTSPEED ULTRA HQT WARNING!! MATERIAL MUST BE PURCHASED FROM MFGING DO NOT GO TO VENDOR AS IT MUST BE TESTED IN MFGING BEFORE SHIPPED TO FIELD VERY VERY HIGH DOA RATE. MS08992 GVR 7/31/00GELS
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.