Unable to Scan Next Series due to Customer Popup Message "recon has not finished.
Symptom
Unable to Scan Next Series due to Customer Popup "recon has not finished. Please wait for completion". All Images Reconstructed. Occurs After 2dtof, MR-Echo, Realtime or Fluoro-trigger Series. See Long Description Unable to scan the next series due to a customer Popup message "recon has not finished. Please wait for completion". But all images are reconstructed. One tech reports that the only way to scan again is to reboot the system. But the techs at two different sites say only a Reset TPS is needed to clear this state. The problem is intermittent. This is reported to occur after 2dtof, MR-Echo, Realtime or Fluoro-trigger series. This error message was logged in the message log when this problem occurred at one site: Wed Aug 27 13:31:33 2008 Error: 2218731 Host: lxmr Process: scn File: MsaScanOpsScrn.m Line: 899 Realtime or Fluoro triggering cannot be started until recon is finished. Please wait for completion FE ran system diags and VRE tests and all passes. Unable to find a hardware problem. Unable to duplicate it with test scans. iTrak #'s submitted 13163839 (14.0 M5), 13186300 (14.0 M5), 13206021 (14.0 M?), 13237536 (15.0 M3), 13277042 (12.0 M5B). Reference SPR #'s MRIhc41081 (14.0 M5), MRIhc39692 (14.0 M5).
Error message
2218731 Realtime or Fluoro triggering cannot be started until recon is finished. Please wait for completion See Long Description Error: 2218731 Host: lxmr Process: scn File: MsaScanOpsScrn.m Line: 899 Realtime or Fluoro triggering cannot be started until recon is finished. Please wait for completion
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.