At End of DC Offsets or Gradient Diagnostics, Message Appears on Screen, X Axis gradient error detected, recovery in pro…
At End of DC Offsets or Gradient Diagnostics, Message Appears on Screen, X Axis gradient error detected, recovery in progress.
Symptom
At End of DC Offsets or Gradient Diagnostics, Message Appears on Screen, X, Y or Z Axis gradient error detected, recovery in progress. See Long Description At the end of DC offset calibration and gradient diagnostics, a brief message appears on screen in the status area indicating a fault was detected. This message may appear for one or all of the gradient axes. The messages appear and then disappear after only two seconds, see below for the messages. These messages are never logged in the system log. The messages were first noticed when the system was installed as a TwinSpeed HDx system (14x software), and persist since the system was upgraded to TwinSpeed HDxT (15x software). But it doesn't seem to be affecting system performance at all otherwise and the customer has not made any complaint. Also all diagnostics and DC offset calibration passes and TPS Reset is always successful. iTrak # 13232664. "X Axis gradient error detected; recovery in progress." "Y Axis gradient error detected; recovery in progress." "Z Axis gradient error detected; recovery in progress."
Error message
X Axis gradient error detected; recovery in progress. See Long Description This brief message appears on screen in the status area. The message appears and then disappears after only two seconds, see below for the message. The message is never logged in the system log. X Axis gradient error detected; recovery in progress. Y Axis gradient error detected, recovery in progress. See Long Description This brief message appears on screen in the status area. The message appears and then disappears after only two seconds, see below for the message. The message is never logged in the system log. Y Axis gradient error detected; recovery in progress. Z Axis gradient error detected, recovery in progress. See Long Description This brief message appears on screen in the status area. The message appears and then disappears after only two seconds, see below for the message. The message is never logged in the system log. Z Axis gradient error detected; recovery in progress.
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.