GE Healthcare · Nuclear MedicineMillennium
Millennium gantry Table Laterals and Radial 2 motions not calibrating
Symptom
Millennium gantry Table Laterals and Radial 2 motions not calibrating
Error message
LATRL axis failed during calibration: GIP_N_FOL_ERR Motion ended because of a following error on the Lateral axis LATRL axis failed during calibration: GIP_N_FOL_ERR 2008/12/30 14:15:43 EST hrdnmg:gip_mx;77:gip_recv.c[$Revision: 1.78.2.1 $] handleEnd() line 1714 error 0x07100005 level 2 "Motion ended because of a following error on the Lateral axis. " 2008/12/30 14:15:43 EST hrdnmg:tgc_mx;71:moveio.c[$Revision: 1.19.4.2 $] mio_gip_n_axis_status() line 1848 error 0x14300004 level 2 "LATRL axis failed during calibration: GIP_N_FOL_ERR" 2008/12/30 14:15:43 EST hrdnmg:gip_mx;77:gip_recv.c[$Revision: 1.78.2.1 $] handleCntlMsg() line 1039 error 0x07100005 level 2 "Right Limit reported on the Lateral axis. " 2008/12/30 14:15:43 EST hrdnmg:tgc_mx;71:calib.c[$Revision: 1.43 $] cal_gip_n_axis_stat_s01() line 590 error 0x14300004 level 2 "LATRL axis failure during calibration: GIP_N_FOL_ERR" 2008/12/30 14:15:44 EST hrdnmg:gip_mx;77:gip_recv.c[$Revision: 1.78.2.1 $] handleCntlMsg() line 1319 error 0x0710003D level 3 "Download: Release=3.0: FW 39-4_02" 2008/12/30 14:15:59 EST hrdnmg:gip_mx;77:gip_recv.c[$Revision: 1.78.2.1 $] handleEnd() line 1714 error 0x07100005 level 2 "Motion ended because
Applies to
- Models
- Millennium
- Product
- MG/MC/Myosight Millennium MG/MC Millennium MyoSIGHT
- Component
- 2146498 Millennium Gantry AMPLIFIER AXIS DRIVE CARD 2146498 Millennium Gantry AMPLIFIER AXIS DRIVE CARD 2146498 Millennium Gantry AMPLIFIER AXIS DRIVE CARD *IPS IPS IPS
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Need part numbers for the Millennium MG/MC table E-Stop
- How do I Delete a file on Genieacq that the system thinks is still acquiring
- VG, the contour works... but in the opposite way.
- MG_MC_MyoSight_MPR_MPS Bar Phantom Resolution Size