GE Healthcare · CTDiscoveryLightSpeed10032
LightSpeed/Discovery CT750 HD
Symptom
Unable to label MOD media - System Pop-up Window reports "Arserver - No Media in the Drive." Unable to label MOD media - Pop-up Window reports "Arserver - No Media in the Drive. "
Error message
Arserver - There is no media in the drive - Pop-up Window See Long Description for example image of error. Arserver - There is no media in the drive - Pop-up Window Error: 10032 Media is not formatted or of unknown format See Long Description for the full error Sun Jun 19 22:29:28 2005 Error: 10032 Host: ct01 Process: arsjob File: ArchiveDevice.c Line: 4677 Media is not formatted or of unknown format
Applies to
- Models
- Discovery, LightSpeed
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 08MW39.4 for Discovery CT750 HD 08MW39.4 for Discovery CT750 HD 11/17/2008 Inital M3 release. 08MW39.4 for Discovery CT750 HD 11/17/2008 Inital M3 release. - Discovery CT750 HD Collector 5323588 Rev 3 includes OS and Application CD's - Operating System Linux 5.3.8 Software CD 5323584 Rev 1 - Application CT750 HD DVD 5323585 Rev 3 ======================================================= - Class C CT750 5233586 Rev 1 - Class M CT750 5323587 Rev 1 An On-site / Remote identification aid . (Example: check_config) Result from check_config or swhwinfo: 08MW39.4.V40_PS_HD64_G_GTM 08MW39.4.V40_PS_HD64_G_GTL
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.