GE Healthcare · CTLightSpeedVCT260100042260100017

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

System will not take any scout or helical scans. Axial scans works. See Long Description for detail Scan hardware stops scan on any scout scan or helical scan attempts with error Timeout on Table gate signal (Cradle Sync Pulse). System would still take axial scans ok. FE indicated that whenever a scout or helical scan was attempted, the gantry would rotate and the table would move as if it was doing the scan, however the xray on indicator would never come on. The error below would then post in the gesyslog: Fri Sep 8 11:48:58 2006 Error: Host: Process: Scan Control File: scTrigSeqActions.c 1.65 Line: 1526 Function: XRAY GENERATION : Table - Gantry Sync Scan: 5564/1/1 Type: Helical Exception Level: Pri/Most Severe Time: 11:48:58:255 Log Series: 132 Timeout on Table gate signal (Cradle Sync Pulse). HW/SW Error: Probable hardware, possible software, problem. (Timeout: 796).

Error message

Error: 260100042 Cradle was NOT ready See the long description for the full error code Tue May 17 16:02:03 2005 Error: 260100042 Host: tgp Process: tgp_subsys File: scHdwRdy.c Line: 70 Tue May 17 16:02:02 2005 Host : Table Gantry Processor Ermes # : 260100042 Exception Class : Soft Severity : Sec/Soft File : scHdwRdy.c Line# : 70 Function : No System Function Reported Scan Type : Scout Scan: 106/1/1 Cradle was NOT ready

Error: 260100017 Minimum required hardware NOT ready during exposure. See LD for more details Error: 260100017 Minimum required hardware NOT ready during exposure. Fri Aug 18 14:17:13 2006 Error: 260100017 Host: tgp Process: tgp_subsys File: scHdwRdy.c Line: 658 Fri Aug 18 14:17:12 2006 Host : Table Gantry Processor Ermes # : 260100017 Exception Class : Abort Severity : Primary File : scHdwRdy.c Line# : 658 Function : No System Function Reported Scan Type : Scout Scan: 6684/1/1 Minimum required hardware NOT ready during exposure. HW/OP/SW Error: Possible hardware, operator, or software problem. A list of hardware that is not ready for views follows:

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5245271 GTCB3 (Global Table Control Board 3) This board replaces 5142177-3 GTCB2 and GTCB part # 5112470 thru 5112470-5, and 5142177. See long description for details Part #: 5245271 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: GTCB3 BOARD ASSY FRU: Yes Status: Orderable Comments: added per to ECO2080741 by sso#305010201 in May 8, 2009. Part will be available end of Sep, 2009, please order old p/n before new p/n on shelf.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues