Lightspeed 1.X - Octane

Symptom

Images would not reconstruct.

Error message

Error: 230003020 Timer expired waiting for image in state BACKPROJECTING See the long description for the full error code Thu Jun 30 23:02:39 2005 Error: 230003020 Host: ip01 sbc Process: igctrl File: igctrl mgr.c Line: 1144 Function: Image Generation : SBC Processing Job Type: Prospective Axial Scan: 26390/2/2 Image: 26390/2/3 Recon Seq Id: 15 Timer expired waiting for image in state BACKPROJECTING

Error: 230006519 Reconmgr timed out waiting for Rebin/Resotre done from Rebin See long description for full error Thu Sep 11 10:27:22 2008 Error: 230006519 Host: ct02_sbc Process: reconmgr File: rm_process_job.c Line: 628 Function: Image Generation : SBC Processing Job Type: Prospective Helical Scan: 40115/2/1 Image: 40115/3/36 Recon Seq Id: 765 Reconmgr timed out waiting for Rebin/Resotre done from Rebin Rebin Setup:0 Rebin Done:0. SDC Setup:0 SDC Done:0.

Error: 230003012 IG unit 0 failed to reset successfully. See long description for full error Tue Sep 9 08:19:33 2008 Error: 230003012 Host: ct2l sbc Process: igctrl File: igctrl mgr. Line: 437 IG unit 0 failed to reset successfully. Retried 2 times. Possible hardware problem. No further attempts to use this IG will be made until the

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2118899-2 RHAPSODE IMAGE GENERATOR Board (IG Board). Used in Lightspeed 1x, CTi 4x, CTi 6x systems. See LD for details Part #: 2118899-2 Part Type: GP REPAIRABLES Part Weight: 3.64 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: RHAPSODE IMAGE GENERATOR FRU: Yes Status: Orderable Comments: FLS - IMAGE GENERATOR BOARD USED ON RHAPSODE MS1356 BURR 12-95 REPLACED 2118899 PER PCN 189598. MS4636 2/6/96 PCN 189939 GELS - KANBAN CSS F00,PCB IMAGE GENERATOR
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.