GE Healthcare · Nuclear MedicineMillennium
No motions on Millennium Gantry, will not Calibrate motions after resetting gantry controller, detector two level at 180…
No motions on Millennium Gantry, will not Calibrate motions after resetting gantry controller, detector two level at 180 degrees.
Symptom
No motions on Millennium Gantry, will not Calibrate motions after resetting gantry controller, detector two level at 180 degrees. Possible may have table motions if shutdown AUI and reset the gantry controller. Gantry Exerciser indicate Gantry Status Unknown. Gantry failed to complete transition.
Error message
Error 44 - Roll axis is not in correct position for transition (GIP E INVAL START POS). "Geometry change failed with error 44" genieacq:gip mx;123:gip util.c[$Revision: 1.64 $] gipVgError() line 1491 error 0x07100013 level 2 severity 3 {} "Roll axis is not in correct position for transition (GIP E INVAL START POS)" Roll axis is not in correct position for transition (GIP E INVAL START POS). "Geometry change failed with error 44" Errorlog example- 2008/11/19 07:20:15 EST genieacq:gip mx;123:gip util.c[$Revision: 1.64 $] gipVgError() line 1491 error 0x07100013 level 2 severity 3 {} "Roll axis is not in correct position for transition (GIP E INVAL START POS)" 2008/11/19 07:20:15 EST genieacq:tgc mx;93:moveio.c[$Revision: 1.21 $] mio gip r transition() line 1444 error 0x14300009 level 3 severity 3 {} "Geometry change failed with error 44" 2008/11/19 07:20:15 EST genieacq:tgc mx;93:calib.c[$Revision: 1.45 $] cal mg failure() line 1077 error 0x14300003 level 2 severity 3 {} "cal gip r xtion s01 gip response to VG transition move = invalid start pos"Applies to
- Models
- Millennium
- Product
- MG/MC/Myosight Millennium MG/MC Millennium MyoSIGHT
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Need part numbers for the Millennium MG/MC table E-Stop
- How do I Delete a file on Genieacq that the system thinks is still acquiring
- VG, the contour works... but in the opposite way.
- MG_MC_MyoSight_MPR_MPS Bar Phantom Resolution Size