Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT20050153320060002520000182120010901220050200116558080

LightSpeed 3.X (Ultra, Plus, QX/i) - GRE

Symptom

Unable to prescribe an exam

Error message

ERROR: 200501533 Event Router process with status: Timed out while attempting to receive a message.. See LD for variations of this error. ERROR: 200501533 Process Timed out while attempting to receive a message. Wed Feb 28 17:51:14 2007 Error: 200501533 Host: ct99 Process: scanRx File: uifIpcCommonFunctions.c Line: 2270 Function: No system function reported Service uif_scan_rx failed to receive message with event code 3141 from Event Router process with status: Timed out while attempting to receive a message. Below is another example of a different process that timed out: Fri Dec 30 10:03:25 2005 200501533 4 ctls16 reconMgmt uifIpcCommonFunctions.c 2269 Function: No system function reported Service uif_recon_mgmt failed to receive message with event code 3123 from Event Router process with status: Timed out while attempting to receive a message. Also saw these in the gesyslog: Fri Dec 30 10:02:48 2005 200600025 2 ctls16 retroRecon UIRxToRetroRequest.cxx 302 Could not send request to Qmanager, EV_QUEUE_SYNOPSIS, status 200001821 From /var/log/messages in the darc: 30 10:01:07 darc kernel: Uhhuh. NMI received for unknown reason 31. Dec 30 10:01:07 darc kernel: Dazed and confused, but

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues