GE Healthcare · CTLightSpeedVCT260134602
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Cradle does not move on GT table or stuck at the home position. Table moves OK, but Cradle will not drive IN or OUT of gantry.
Error message
Error: 260134602 Cradle drive torque setting error See Long Description for error example Mon Dec 26 10:41:58 2005 Error: 260134602 Host: tgp Process: tgp_subsys File: gtcb_cmc_drv_req.cxx Line: 928 Mon Dec 26 10:41:58 2005 Host : Table Sub-System Ermes # : 260134602 Exception Class : Secondary Severity : Pri/Soft File : gtcb_cmc_drv_req.cxx Line# : 928 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle drive torque setting error
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5314448-2 (replaces 5114128) Cradle Driver Cable Positioning GT J204 See long description for details Part #: 5314448-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Cradle Driver Cable Positioning GT FRU: Yes Status: Orderable Old FRU Compatible Yes Comments added per to ECR2087052 by sso#305010201 in Sep 3, 2009 Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5314448-2 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number 2087052 Part #: 5114128 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: CRADLEDRIVER TO J204 FRU: Yes Status: Orderable Comments: source pole/planner code revised per to Global Table transfer
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required