GE Healthcare · CT
Scan Aborts and will not resume
Symptom
Scan Aborts and will not resume
Error message
ER-117 XG Fail - contains information on all XG ER117 errors See Long Description ER-117 XG Fail ER–117 ER – 117 : XG Error 00000XYY Error Code X = _ 0: Test Mode 1: Stand–by 2: Preparation Acting 3: Generator Ready 5: Exposure 7: Transition Step to Stand–by ER–117 (continued) ER – 117 : XG Error 00000XYY Error Code YY = _ X01: No DC550V X02: 15V_Safe Error X03: Over Voltage Capacity X11: Rotor Controller Error X12: Rotor Acceleration Error X13: Rotor Feedback Test X14: Rotor Fault Detect Test X16: Low Current Error X18: Unbalance Error X21: Over Filament Current 021: Feedback Test X22: No Filament Current 022: Fault Detect Test X23: Bad Relay Return 023: Small Focus Test X24: No Filament Voltage 024: Large Focus Test X25: Filament Control Error 526: MA measure Error 031: Feedback Test 032: Fault Detector Test 033: Close Loop Test 531: MA Accuracy Error 532: KV Accuracy Error 533: Spit Error 534: Exposure Backup Timer Error 535: Anode Over mA 536: Cathode Over mA 537: Anode Over kV 538: Cathode Over kV 539: Anode Shoot Through 540: Cathode Shoot Through 541: Anode Over Current 542: Cathode Over Current X43: HV ON with Error 544: KV Unbalanced Error X48: Generator Safety Loop Open X
Applies to
- Product
- ProSpeed Qj and Zj (Lemage, Qj, Qj-Base, Qj-Hlt) ProSpeed Qj and Zj (Lemage, Qj, Qj-Base, Qj-Hlt) ProSpeed Qj and Zj (Lemage, Qj, Qj-Base, Qj-Hlt) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 45435961 CTVRC // (aka 2122768-2 see LD for why) - used on HSA, CTi and YMS Prospeed see long description Part #: 45435961 Part Type: GP REPAIRABLES Part Weight: 41.89 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: CTVRC// 2122768-2 FRU: Yes Status: Orderable FLS - H&F:THIS IS THE NON-EMC CTVRC.THE MODULE HAS 8 JUMPERS WHICHWILL ALLOW CONVERSION FROM A HSA CTVRC TO A ZJ CTVRC. THE ITEM IS STOCKED WITH JUMPERS IN THE CORRECT LOCATION FOR HSA. PER HARRY LEWIS 6/94. ============================================================HQ: IF NO STOCK, YOU CAN SHIP T3202GH EMC CTVRC. T3202GH ISBACKWARDS COMPATIBLE. NEVER SHIP T3202CB IN PLACE OF T3202GH. T3202CB CANNOT BE UPGRADED. MS8365 2/95 ============================================================ HQ INFO ONLY: PCN 189116 CHANGED EQV # FOR T3202CB FROM 45435961 TO 2106148. CTVRC=CT VOLTAGE REGULATOR CONTROL.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required