GE Healthcare · CTLightSpeed260112011
LightSpeed 5.X (60kW)
Symptom
Cradle drive motor is running, but cradle will not move. Cradle drive motor is running, but cradle will not move
Error message
Error: 260112011 Received Table Rx but the Table was NOT READY Error : 260112011 Received Table Rx but the Table was NOT READY Thu Sep 1 08:49:43 2005 Error: 260112011 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr.c Line: 3197 Thu Sep 1 08:49:44 2005 Host : Table Gantry Processor Ermes # : 260112011 Exception Class : Soft Severity : Pri/Soft File : uif_table_tilt_mgr.c Line# : 3197 Function : No System Function Reported Scan Type : Helical Scan: 8439/4/1 Received Table Rx but the Table was NOT READY for Scanning.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2372372 Right Table Top Cover - used on LS 2.x - 5.x tables See LD for details 2372372 HPower Right Table Top Cover Part #: 2372372 Part Type: GP CONSUMABLES Part Weight: 72.75 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER TABLE TOP RIGHT FRU: Yes Status: Orderable Comments: FLS - COVER TABLE, TOP RIGHT. REPLACES P/N 2236720-2 ONLY ON HPOWER SYSTEMS, PER CT PCN 220864. MS20544 3/31/03. Addtional Right Table Top Cover Information: Part #: 2236720-2 <-- Use this part # for 1.x, 2.x, 3.x, 4.x and HiSpeed QXi Systems Part Type: GP CONSUMABLES Part Weight: 25.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER ASSEMBLY TABLE TOP - RIGHT FRU: Yes Status: Orderable Comments: FLS - COVER ASSEMBLY TABLE TOP-RIGHTU/O LIGHTSPEED & PET TABLE 6/30/99 MS08992 THIS REPLACED THE 2149735 PER CHRIS DOERING MSA1248 10/99 GPC TABLE MOVED TO CHINA 5/24/01 NOW ASIA SOURCED THIS P/N HAS BEEN REPLACED BY P/N 2372372 (ONLY APPLICABLE ON HPOWER SYSTEMS) PER PCN 220864. MS20544 3/31/03. DIMS: 90" LONG; 70" WIDE FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA
- Area
- CT