GE Healthcare · CTLightSpeed

Unable to hear patients thru intercom intermittently.

Symptom

Unable to hear patients thru intercom intermittently. Unable to hear patients thru intercom intermittently.

Applies to

Models
LightSpeed
Product
LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2111955-2 (replace 2111955) P9213YX MIC ASSY (Gantry intercom microphone assembly) See long description for more information. Part #: 2111955-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: MIC BD ASSY FRU: Yes Status: Orderable Comments:. Per Dayton RSPL, 212008898, 2/3/2010. Old FRU Compatible No Comments Per Dayton RSPL, 212008898, 6/4/2010. Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 2111955-2 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Direct ECO Number BKS09596 2111955 P9213YX MIC ASSY (Gantry intercom microphone assembly) < Part #: 2111955 Part Type: GP CONSUMABLES Part Weight: 0.99 LBR Repairable: No Returnable: No Hazardous Material: N Description: P9213YX MIC ASSY FRU: Yes Status: Orderable Availability: Current GMT: 22-Sep 22:34 Comments: FLS - MIC ASM USED ON QJ HLT ZJ ADVANTAGE SYJ (SYTEC 1800I) &amp; SYTEC-SRI GANTRY STA 8/21/95 *THIS MIC ASM INCLUDES THE U0009ER MIC PLUS THE CABLE AND PLUG. STA 6/18/96 USED ON HPOWER PROGRAM PER RSPL. MS20544 ON 2/12/03. 2320719 GANTRY INTERCOM II See long description for details Part #: 2320719 Part Type: GP CONSUMABLES Part Weight: 9.92 LBR Repairable: No Returnable: No Hazardous Material: N Description: GANTRY INTERCOM II FRU: Yes Status: Orderable Comments: ** FE ASSIST ** This part requires SP2 07MW11.10_GEHCServicePack2-0-26, or 07MW18.4_GEHCServicePack2-0-26 or 07BW08.4_GEHCServicePack2-0-26, or later software to support required flashdownload updates. (212001261 8/28/09) FLS - GANTRY INTERCOM II. USE OLD P/N (2286305) FIRST,THEN USE NEW P/N. ADDED PER PCN22033 ON 12/05/01 BY MS20544, CSV. REWORK CURRENT STOCK TO NEW BDTYPE. THIS CHANGE IS DUE TO
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues