GE Healthcare · CTLightSpeedVCT26013275850132
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Unable to do a tube warm-up. Unable to do a tube warm-up
Error message
Error: 260132758 Digital Interface Board(s) Have Detected Missing or Faulty Digital Modules See Following Error Message for Digital Interface Board List Digital Module BitMap: 12 Ermes # : 260132758 Digital Interface Board(s) Have Detected Missing or Faulty Digital Modules See Following Error Message for Digital Interface Board List Digital Module BitMap: 12 Host : Das Ermes # : 260132758 Exception Class : Abort Severity : Secondary File : Ifb.cxx Line# : 623 Function : No System Function Reported Scan Type : Static Scan: 50132/1/2 Digital Interface Board(s) Have Detected Missing or Faulty Digital Modules See Following Error Message for Digital Interface Board List Digital Module BitMap: 12
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5129366 cable, 48vdc pwr - Fuse board to das, used on vct See long description for details Part #: 5129366 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: cable, 48vdc pwr with special jackscrews, das, vct FRU: Yes Status: Orderable Comments: Added per VCT M4 RSPL Update, ms13452 060206
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.