GE Healthcare · CTLightSpeedVCT26011202250219
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Unable to do tube warm up, hear ticking from speaker on console UNABLE TO DO TU BE WARM UP,HEAR TICKING FROM SPEAKER ON CONSOLE
Error message
Error: 260112022 Communication between the TGP and Console Pushbuttons (SCIM) are down See long description for full error Wed Sep 10 00:06:08 2008 Error: 260112022 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 5089 Wed Sep 10 00:06:08 2008 Host : Table Gantry Processor Ermes # : 260112022 Exception Class : Secondary Severity : Pri/Soft File : uif_table_tilt_mgr_gt.c Line# : 5089 Function : No System Function Reported Scan Type : Axial Scan: 50219/1/1 Communication between the TGP and Console Pushbuttons (SCIM) are down
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2404320 CONSOLE INTERCOM PRESCRIBED-TILT HUB See Long description for details Part #: 2404320 Part Type: GP CONSUMABLES Part Weight: 21.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: CONSOLE INTERCOM PRESCRIBED-TILT HUB FRU: Yes Status: Orderable Comments: ** FE ASSIST ** CT/Pet Discovery systems must use 2404320. Recommended for CT Systems to order 2404320-2 , to avoid gantry lights being displayed when console is shut down. FMI 25407 or 22918 must be loaded prior to using the 2404320-2. (212001261 10/21/08) Added per VCT RSPL, ms13452 041209 __Set as Critical Part for Product CT_VCT, ms04278, 05Oct14
- Area
- CT
Full cause & step-by-step resolution