LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Customer was not able to remote tilt gantry. In many cases , gantry will tilt from the Gantry Controls.

Error message

Error: 260112014 Touch sensor ? Touch Sensor was PRESSED See Long Description for full error Error: 260112014 Touch sensor ? Touch Sensor was Pressed. Sun Mar 12 15:14:25 2006 Error: 260112014 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 9013 Sun Mar 12 15:14:24 2006 Host : Table Gantry Processor Ermes # : 260112014 Exception Class : Secondary Severity : Sec/Soft File : uif_table_tilt_mgr_gt.c Line# : 9013 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 0/0/0 Touch sensor BACK Touch Sensor was PRESSED. Elevation position where touch Sensor was Pressed:0 um. Tilt position where touch sensor was pressed:0 mdeg. Remote Tilt button is DISABLED. Use local gantry controls to tilt the gantry. Or Mon Apr 9 09:29:44 2007 Error: 260112014 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr.c Line: 9990 Mon Apr 9 09:29:44 2007 Host : Table Gantry Processor Ermes # : 260112014 Exception Class : Secondary Severity : Pri/Soft File : uif_table_tilt_mgr.c Line# : 9990 Function : PATIENT ANATOMY POSITIONING : Elevation Drive Scan Type : None/Unknown Scan: 317/6/0 Touch sensor FORWARD Touch Sensor was PRESSED. Elevation position where touch 

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5134416 Front Cover Sensor, Patient Tilt, Small, 175mm long tail with bend for low profile cover routing (For VCT) See long decription for details Sensor, Patient Tilt, Small, 175mm long tail with bend for low profile cover routing Part #: 5134416 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Sensor, Patient Tilt, Small, 175mm long tail with bend for low profile cover routing FRU: Yes Status: Orderable Comments: Added per iTrak: 13056981. ms13452 060228
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required