AUI can freeze when Millennium Genieacq scan is stopped manually or interrupted by collision or motion error with softwa…
AUI can freeze when Millennium Genieacq scan is stopped manually or interrupted by collision or motion error with software 4.5.
Symptom
AUI can freeze when Millennium Genieacq scan is stopped manually or interrupted by collision or motion error with software 4.5. Problem seems to occur for scans that are set to terminate on time. PSDB NM Knowledge Session AUI can freeze when Millennium Genieacq scan is stopped manually or interrupted by collision or motion error with software 4.5. Problem seems to occur for scans that are set to terminate on time. The setup parameters are defined by software and include a termination detector combination of "Last" even though that is meaningless for the scans set to terminate on time. Interrupting the scan via any motion stops, collisions, or pressing "Stop" during a normal scan causes the AUI to appear to freeze. Typically if the operator will wait long enough the system will recover but could be several minutes depending on length of original scan time. This condition can be created by the user through the UI when modifying a scan that terminates on counts "Last" into one that terminates on time. The issue can seem very intermittent since it may not be using the same template for different scans and does not freeze if scan is not interrupted. The issue is specific to the template used for the scan.
Applies to
- Models
- Millennium
- Product
- MPR/MPS Millennium MPR Millennium MPS MG/MC/Myosight Millennium MG/MC Millennium MyoSIGHT
- Software
- GenieAcq R4.5 V14 (M4) Genieacq 4.5 Build 14 (M4) 5220379 Genieacq SW R4.5 V014 M4 with accumulative patches GA450-05-1, GA450-6-1, GA450-07-0, GA450-08-1, and GA450-09-0 for Spare Part GENIE Acq R 4.5 V014 supports EDI and I/N board hardware configurations. The following computer platforms are supported by this version: SuperMicro P4SBR ( only supports the EDI detctor, reference SN43628 ) IBM x205 Dell 1400SC Dell GX200 Dell 1300. Dell 2200 and Intel AltServer are not supported. Reference CIS 5150522-100_r2
- Component
- *Software Software Software
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Need part numbers for the Millennium MG/MC table E-Stop
- How do I Delete a file on Genieacq that the system thinks is still acquiring
- VG, the contour works... but in the opposite way.
- MG_MC_MyoSight_MPR_MPS Bar Phantom Resolution Size