GE Healthcare · CTLightSpeedVCT2601120161250010000
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Gantry tilts slowly 1 degree and stops - table moves very slowly 5mm and stops. Gantry tilts slowly 1 degree and stops - table moves very slowly 5mm and stops
Error message
Error: 260112016 Gantry forward touch sensor was pressed , Gantry can only tilt in the forward direction till XXX deg See Long Description for complete error. Mon Jan 21 14:56:59 2008 Error: 260112016 Host : Table Gantry Processor Ermes # : 260112016 Exception Class : Secondary Severity : Pri/Soft Gantry forward touch sensor was pressed at -12500 mdeg. Gantry can only tilt in the forward direction till -10000 mdeg.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2277404 Patient Tilt Sensor, Large for Rear Gantry Cover used on HiSpeed QXi, 2.x(Plus), 3.x(Ultra), 4.x(16 Slice), HPower and VCT gantries See Long Description for Part Details 2277404 Patient Tilt Sensor, Large for Gantry REAR Cover Asm. Part #: 2277404 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: PATIENT TILT SENSOR, LARGE FRU: Yes Status: Orderable Comments: FLS - H2 GANTRY. COMMON TO MFG MS26561 DSM 1/7/01 REAR LARGE SWITCH/PART OF 2273016 REAR GANTRY COVER COLLECTION OF DEFECTIVES START7/23/01 MS5277
- Area
- CT