GE Healthcare · CTLightSpeedVCT260134602

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Intermittent cradle drive error and table reset during cradle or elevation movement Cradle (intermittently) starts with a jerky movement, immediately followed by a table power cycle. After about 15 sec the table is available again for a movement. The table power cycle can also occur (intermittently) during lowering the table if the cradle (not IMS) was not at home position before down movement.

Error message

Error: 260134602 Cradle drive torque setting error See Long Description for error example Mon Dec 26 10:41:58 2005 Error: 260134602 Host: tgp Process: tgp_subsys File: gtcb_cmc_drv_req.cxx Line: 928 Mon Dec 26 10:41:58 2005 Host : Table Sub-System Ermes # : 260134602 Exception Class : Secondary Severity : Pri/Soft File : gtcb_cmc_drv_req.cxx Line# : 928 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle drive torque setting error

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5314448-2 (replaces 5114128) Cradle Driver Cable Positioning GT J204 See long description for details Part #: 5314448-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Cradle Driver Cable Positioning GT FRU: Yes Status: Orderable Old FRU Compatible Yes Comments added per to ECR2087052 by sso#305010201 in Sep 3, 2009 Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5314448-2 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number 2087052 Part #: 5114128 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: CRADLEDRIVER TO J204 FRU: Yes Status: Orderable Comments: source pole/planner code revised per to Global Table transfer
Area
CT