GE Healthcare · CTLightSpeed2601010572600073842601010985000126010102350444

LightSpeed 5.X (80/100kW)

Symptom

Scan hardware stopped scan with RCIB errors

Error message

Error: 260101057 RCIB Fault Line failure detected This Error has variables - See LD for details Error: 260101057 RCIB Fault Line failure detected Error Example: (see below for explanation ) Tue Jan 3 11:05:44 2006 Host : On-Board Rotating Processor Ermes # : 260101057 Exception Class : Secondary Severity : Pri/Soft File : rcib_fault_status.c Line# : 189 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 RCIB Fault Line failure detected. The status of the fault bus is as follows: Parallel or Serial Fault line: [1=Fault 0=OK -1=Unknown] Command: [1=Fault Asserted 0=OK -1=Unknown] (Note: An unknown status is due to message failure.) ORP fault status: 0 [1=serial or parallel fault set. 0=OK] Node Parallel Serial Command --------------------------------- ORP - 1 -1 CCB 0 1 0 DCB 0 1 0 EN 817 Error explanation/decode : Host: orp Process: orp_subsys File: rcib_fault_status.c Line: 189 Exception Class : Secondary Severity : Pri/Soft File : rcib_fault_status.c Line# : 189 Function : No System Function Reported Scan Type : None/Unknown Scan: 5/1/0 RCIB Fault Line failure detected. The status of the fault bus is as follows: Parallel or Serial Fault line: [1=Fault 0=OK

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2361853-2 GDAS DCB 16-SLICE replaces 2361853 See LD for more Info 2361853-2 GDAS DCB 16-SLICE replaces 2361853 Part #: 2361853-2 Part Type: GP CONSUMABLES Part Weight: -59999.40 LBR Repairable: No Returnable: No Hazardous Material: N Description: GDAS DCB FRU: Yes Status: Orderable FLS - GDAS DCB (16-SLICE) USED ON: LIGHTSPEED PRO 16 GDAS ADDED PER GDAS RSPL MS13452 This board has been replaced by 2361853-2, FE NOTE: Site MUST have M4FMI completed before this board will function properly, ms13452
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required