LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Partial ring artifact - helical scan - near iso center, 32 or 64 slice image. See long description for image artifact Partial ring artifact - helical scan - near iso center, 32 or 64 slice image. On smaller slice systems the ring would be more obvious. Each of these images contain 1/64 of the ring.

Error message

Error: 230007014 Uncorrectable detector channels have been found for scan See LD for an example of entire error message. Fri Oct 28 09:32:03 2005 Error: 230007014 Host: presbyplano Process: badchanmgr File: badchanmgr.cxx Line: 1194 Uncorrectable detector channels have been found for scan 50029/2/2

Error: 230007001 Exclusion Test - Row xx:xxx, Channel xxx, Module xx Open Channel* FAILED X-AXIS EXCLUSION CRITERIA Mon Oct 3 11:30:58 2005 Error: 230007001 Host: ctm1 Process: badchanmgr File: BadChannelMap.cxx Line: 544 Exclusion Test - Row xx:xxx, Channel xxx, Module xx Open Channel* FAILED X-AXIS EXCLUSION CRITERIA *.

Error: 230007013 Density Check - Module xx exceeds number of opens allowed (1 > 0). Mon Oct 3 11:30:58 2005 Error: 230007013 Host: ctm1 Process: badchanmgr File: DensityMap.cxx Line: 77 Density Check - Module xx exceeds number of opens allowed (1 > 0).

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5196401 FRDM for Center Modules for HDAS-64 see long description 5196401 HDAS FRDM Center Modules (Qty 57 used) Part #: 5196401 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: V-RES FIELD REPLACEABLE MODULE KIT - INNER SLOTS HALO CONVERTER CARD FRU: Yes Status: Orderable
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.