GE Healthcare · CTLightSpeedVCTBrightSpeed200109169200109170
Pop-up appears upon boot-up
Symptom
Pop-up appears upon boot-up: An unrecognized X-Ray tube has been installed on the system.
Error message
Error: 200109169 An unrecognized X-Ray tube has been installed on the system. See Long Description for more details Sat Jun 17 07:43:15 2006 Error: 200109169 Host: ct02 Process: scanRx File: SIRx.cxx Line: 663 Function: Data Acquisition : OC Processing Tube identity advisory: An unrecognized X-Ray tube has been installed on the system. GE Medical Systems cannot assure that the system performance will conform to specifications. Error: 200109170 Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration,and in the dose report. See Long Description for complete error Mon Apr 23 18:16:02 2007 Error: 200109170 Host: ct01 Process: scanRx File: SIRx.cxx Line: 666 Function: Data Acquisition : OC Processing Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration,and in the dose report.
Applies to
- Models
- LightSpeed, VCT, BrightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required