Senographe 700T / 800T Service Manual

FSELIB authored service atoms

FSELIB authored service atoms for the GE Senographe 700T and 800T mammography systems: 55 of the Service Manual's 77 job cards — the complete IST installation series (all 13) and the complete set of cover-removal cards, plus CAL calibration and DR disassembly/re-assembly — rewritten as service atoms, the merged 315-code error list (1996 Service Manual fused with the 2007 Advanced Service Manual, which adds the suspect board and a service action per code), the 22-board map, and the ASM Troubleshooting Guide for the generator, the gantry and the boot sequence. Safety levels are graded to ANSI Z535 against the manufacturer's own printed signal words. The remaining CAL and DR job cards are being added in waves. This service manual covers installation, calibration, troubleshooting and maintenance procedures for the GE Medical Systems Senographe 700T / 800T.

Also known as: GE, GE Medical Systems, GE Healthcare, Senographe, 700T, 800T, Senographe 700T, Senographe 800T, mammography, mammografia, mamografo, breast imaging

Start free trial →

Access 991+ technical service manuals — 7-day free trial, no credit card required.

991+ manuals · 13+ manufacturers · CT, MRI, Mammography, X-Ray & more

Technical Specifications

ManufacturerGE Medical Systems
Equipment TypeMammography
Part Number
sm 2146692-100 REV 5/6 + asm 2149145-8EN Rev. 1 (2007)
RevisionFSELIB 2026-09
Models Covered
Senographe 700TSenographe 800T

Table of Contents

From actual manual
1Which calibration to run after changing a board (Job Card DR 027)
Start free trial →
2Senographe board map: location, part number and the errors that point at each board
Start free trial →
3Senographe boot and system initialization troubleshooting
Start free trial →
4Replace the RAM back-up battery (Job Card DR 004)
Start free trial →
5General errors during the calibration (Job Card CAL 023)
Start free trial →
6Run the Senographe preliminary testing (Job Card IST 009)
Start free trial →
7Configure the software (Job Card IST 010)
Start free trial →
8Verify the jumpers and switches (Job Card IST 007)
Start free trial →
9Replace the LED display panel, 800T only (Job Card DR 029)
Start free trial →
10Senographe 700T / 800T error codes
Start free trial →
11Installation form — 6-parameter software (Job Card IST 011A)
Start free trial →
12Installation form — 9-parameter software (Job Card IST 011B)
Start free trial →
13Fit the safety labelling to the control console (Job Card IST 008)
Start free trial →
14Replace the emergency stop button (Job Card DR 010)
Start free trial →
15Senographe service function keys and the options dataflash
Start free trial →
16Replace the arm rotation box assembly (Job Card DR 009)
Start free trial →
17Replace the magnification board 200PL6 (Job Card DR 023)
Start free trial →
18Replace the counterweight belts (Job Card DR 007)
Start free trial →
19Remove and re-install the cabinet covers (Job Card DR 001)
Start free trial →
20Remove and re-install the cabinet covers, and connect the console (Job Card IST 003)
Start free trial →
21Remove and re-install the column covers (Job Card DR 005)
Start free trial →
22Remove and re-install the examination arm covers (Job Card DR 017)
Start free trial →
23Remove and re-install the tube housing spacer covers (Job Card DR 011)
Start free trial →
24Replace an examination arm handle (Job Card DR 026)
Start free trial →
25Replace the protective glass (Job Card DR 028)
Start free trial →
26Set the elevator upper travel limit (Job Card CAL 011)
Start free trial →
27Physically install the Senographe and fit the protective glass (Job Card IST 002)
Start free trial →
28Unpack the equipment and check it (Job Card IST 001)
Start free trial →
29Senographe arm, compression and light signal troubleshooting
Start free trial →
30Replace the filter assembly (Job Card DR 012)
Start free trial →
31Replace the collimator detection board 200PL2 (Job Card DR 016)
Start free trial →
32Calibrate the kV scale factor (Job Card CAL 017)
Start free trial →
33Calibrate the x-ray tube mA measurement (Job Card CAL 016)
Start free trial →
34Run the automatic x-ray tube warm-up (Job Card CAL 010)
Start free trial →
35Check and adjust the centering device lamp (Job Card CAL 025)
Start free trial →
36Check the pre-exposure thickness prediction in AOP mode (Job Card IST 012)
Start free trial →
37Calibrate the x-ray tube focal bias voltage factor (Job Card CAL 002)
Start free trial →
38Senographe generator troubleshooting: rotor, bias, HV and the DC/DC converter
Start free trial →
39Replace the HV tank (Job Card DR 003)
Start free trial →
40Replace the halogen lamp (Job Card DR 014)
Start free trial →
41Replace the mirror assembly (Job Card DR 015)
Start free trial →
42Calibrate the x-ray tube heater current (Job Card CAL 003)
Start free trial →
43Replace the x-ray tube (Job Card DR 013)
Start free trial →
44Calibrate reference energy for a screen pair (Job Card CAL 014A)
Start free trial →
45Calibrate photomultiplier cell gain for a screen pair (Job Card CAL 007A)
Start free trial →
46Replace the Bucky grid (Job Card DR 024)
Start free trial →
47Check the x-ray film format geometry (Job Card CAL 021)
Start free trial →
48Replace the 200PL5 HTPM board (Job Card DR 032)
Start free trial →
49Replace the photomultiplier tube (Job Card DR 031)
Start free trial →
50Select and configure a screen pair (Job Card CAL 006)
Start free trial →
51Measure, adjust and check the +5V LVPS (Job Card CAL 024)
Start free trial →
52Check the basic power supply voltages (Job Card IST 006)
Start free trial →
53Connect the mains supply (Job Card IST 004)
Start free trial →
54Replace the mains (AC supply) filter (Job Card DR 002)
Start free trial →
55Connect the room lamps and room door (Job Card IST 005)
Start free trial →
56Replace the 300PL9 PSU board, diode bridge and resistor (Job Card DR 030)
Start free trial →
57Replace the low voltage PSU assembly 300PL7 (Job Card DR 033)
Start free trial →
58Replace the encoder board and disc assembly (Job Card DR 022)
Start free trial →
59Replace the compression motor assembly (Job Card DR 018)
Start free trial →
60Replace the compression drive belt (Job Card DR 019)
Start free trial →
61Replace the compression sensor board 200PL7 (Job Card DR 021)
Start free trial →

61 sections · Full content available after sign in

Frequently asked questions

Where can I access the GE Medical Systems Senographe 700T / 800T service manual?▾

The full Senographe 700T / 800T service manual is on FSELIB — the field-service engineering library for medical imaging. Sign in or start a 7-day free trial to open the complete manual: installation, calibration, troubleshooting, error codes and replacement procedures.

What does the Senographe 700T / 800T service manual cover?▾

It covers Which calibration to run after changing a board (Job Card DR 027), Senographe board map: location, part number and the errors that point at each board, Senographe boot and system initialization troubleshooting, Replace the RAM back-up battery (Job Card DR 004), General errors during the calibration (Job Card CAL 023), Run the Senographe preliminary testing (Job Card IST 009) and more for the GE Medical Systems Senographe 700T / 800T (Mammography).

Is the Senographe 700T / 800T service manual free to download?▾

Access is by subscription, with a 7-day free trial. FSELIB hosts authored, web-first service documentation (searchable procedures, diagrams and error-code references) — not a scraped PDF.