Senographe 700T / 800T Service Manual

FSELIB authored service atoms

FSELIB authored service atoms for the GE Senographe 700T and 800T mammography systems: 42 of the Service Manual's 77 job cards (IST installation, CAL calibration and DR disassembly/re-assembly) rewritten as service atoms, the merged 315-code error list (1996 Service Manual fused with the 2007 Advanced Service Manual, which adds the suspect board and a service action per code), the 22-board map, and the ASM Troubleshooting Guide for the generator, the gantry and the boot sequence. The remaining job cards are being added in waves. This service manual covers installation, calibration, troubleshooting and maintenance procedures for the GE Medical Systems Senographe 700T / 800T.

Also known as: GE, GE Medical Systems, GE Healthcare, Senographe, 700T, 800T, Senographe 700T, Senographe 800T, mammography, mammografia, mamografo, breast imaging

Start free trial →

Access 592+ technical service manuals — 7-day free trial, no credit card required.

592+ manuals · 11+ manufacturers · CT, MRI, Mammography, X-Ray & more

Technical Specifications

ManufacturerGE Medical Systems
Equipment TypeMammography
Part Number
sm 2146692-100 REV 5/6 + asm 2149145-8EN Rev. 1 (2007)
RevisionFSELIB 2026-09
Models Covered
Senographe 700TSenographe 800T

Table of Contents

From actual manual
1Senographe board map: location, part number and the errors that point at each board
Start free trial →
2Senographe boot and system initialization troubleshooting
Start free trial →
3Replace the RAM back-up battery (Job Card DR 004)
Start free trial →
4Replace the LED display panel, 800T only (Job Card DR 029)
Start free trial →
5Senographe 700T / 800T error codes
Start free trial →
6Fit the safety labelling to the control console (Job Card IST 008)
Start free trial →
7Senographe service function keys and the options dataflash
Start free trial →
8Replace the arm rotation box assembly (Job Card DR 009)
Start free trial →
9Replace the magnification board 200PL6 (Job Card DR 023)
Start free trial →
10Replace the counterweight belts (Job Card DR 007)
Start free trial →
11Remove and re-install the cabinet covers, and connect the console (Job Card IST 003)
Start free trial →
12Replace the protective glass (Job Card DR 028)
Start free trial →
13Physically install the Senographe and fit the protective glass (Job Card IST 002)
Start free trial →
14Senographe arm, compression and light signal troubleshooting
Start free trial →
15Replace the filter assembly (Job Card DR 012)
Start free trial →
16Replace the collimator detection board 200PL2 (Job Card DR 016)
Start free trial →
17Calibrate the kV scale factor (Job Card CAL 017)
Start free trial →
18Calibrate the x-ray tube mA measurement (Job Card CAL 016)
Start free trial →
19Run the automatic x-ray tube warm-up (Job Card CAL 010)
Start free trial →
20Check and adjust the centering device lamp (Job Card CAL 025)
Start free trial →
21Calibrate the x-ray tube focal bias voltage factor (Job Card CAL 002)
Start free trial →
22Senographe generator troubleshooting: rotor, bias, HV and the DC/DC converter
Start free trial →
23Replace the HV tank (Job Card DR 003)
Start free trial →
24Replace the halogen lamp (Job Card DR 014)
Start free trial →
25Replace the mirror assembly (Job Card DR 015)
Start free trial →
26Calibrate the x-ray tube heater current (Job Card CAL 003)
Start free trial →
27Replace the x-ray tube (Job Card DR 013)
Start free trial →
28Calibrate reference energy for a screen pair (Job Card CAL 014A)
Start free trial →
29Calibrate photomultiplier cell gain for a screen pair (Job Card CAL 007A)
Start free trial →
30Replace the Bucky grid (Job Card DR 024)
Start free trial →
31Replace the 200PL5 HTPM board (Job Card DR 032)
Start free trial →
32Replace the photomultiplier tube (Job Card DR 031)
Start free trial →
33Check the basic power supply voltages (Job Card IST 006)
Start free trial →
34Connect the mains supply (Job Card IST 004)
Start free trial →
35Replace the mains (AC supply) filter (Job Card DR 002)
Start free trial →
36Connect the room lamps and room door (Job Card IST 005)
Start free trial →
37Replace the 300PL9 PSU board, diode bridge and resistor (Job Card DR 030)
Start free trial →
38Replace the low voltage PSU assembly 300PL7 (Job Card DR 033)
Start free trial →
39Replace the encoder board and disc assembly (Job Card DR 022)
Start free trial →
40Replace the compression motor assembly (Job Card DR 018)
Start free trial →
41Replace the compression drive belt (Job Card DR 019)
Start free trial →
42Replace the compression sensor board 200PL7 (Job Card DR 021)
Start free trial →

42 sections · Full content available after sign in

Frequently asked questions

Where can I access the GE Medical Systems Senographe 700T / 800T service manual?

The full Senographe 700T / 800T service manual is on FSELIB — the field-service engineering library for medical imaging. Sign in or start a 7-day free trial to open the complete manual: installation, calibration, troubleshooting, error codes and replacement procedures.

What does the Senographe 700T / 800T service manual cover?

It covers Senographe board map: location, part number and the errors that point at each board, Senographe boot and system initialization troubleshooting, Replace the RAM back-up battery (Job Card DR 004), Replace the LED display panel, 800T only (Job Card DR 029), Senographe 700T / 800T error codes, Fit the safety labelling to the control console (Job Card IST 008) and more for the GE Medical Systems Senographe 700T / 800T (Mammography).

Is the Senographe 700T / 800T service manual free to download?

Access is by subscription, with a 7-day free trial. FSELIB hosts authored, web-first service documentation (searchable procedures, diagrams and error-code references) — not a scraped PDF.

Related Manuals

💬 Forum Discussions about this Model