DPX-IQ Service Manual

FSELIB authored service atoms

FSELIB authored service atoms for the GE Lunar DPX-IQ bone densitometer (DEXA): the complete chapter 4 board-by-board technical description (AMP, AGS, DCA, MAX, XORB, SBC, OINK, OMI and Laser — circuit function, signal path, full test-point tables and the manual's own oscilloscope captures), the DIAGS service utility, error log and ERRDUMP, daily QA with the calibration standard, quick collimation ratio, Static Counter, peak adjustment and the AGS test, tube head and collimator assembly replacement, cable bundle and control cable replacement, transverse drive mechanics and the chapter 8 troubleshooting set. Built from the scanned service manual read page by page, the operator's manual, the DPX Series service training deck and real field capture. Also the collimator selection failure that takes out the forearm program, and how to make the DOS software print to a modern USB printer. This service manual covers installation, calibration, troubleshooting and maintenance procedures for the GE Lunar DPX-IQ.

Also known as: GE, Lunar, GE Lunar, DPX, DPX-IQ, DPXIQ, DPX IQ, densitometer, bone densitometry, DEXA, DXA, osteoporosis

Start free trial →

Access 991+ technical service manuals — 7-day free trial, no credit card required.

991+ manuals · 13+ manufacturers · CT, MRI, Mammography, X-Ray & more

Technical Specifications

ManufacturerGE Lunar
Equipment TypeBone Densitometry
Part Number
DPX-IQ Service Manual Rev. A/B/E + Operator's Manual + DPX Series Service Training (Rev. F 2/2006) + DPX-NT/MD+ SM (corroboration)
RevisionFSELIB 2026-09
Models Covered
DPX-IQDPX-IQ 180DPX-IQ 240

Table of Contents

From actual manual
1The AMP board: how the PMT pulse is built, and where to put the probe
Start free trial →
2Run the AGS test, and adjust only if it is justified
Start free trial →
3The AGS-05 board: signal path, test points and what TP12 is telling you
Start free trial →
4Air counts: unstable, none, or decreasing
Start free trial →
5Adjust the detector peak (HV ADJ - R43)
Start free trial →
6The DCA board: how the scanner decides which photon it just saw
Start free trial →
7Imaging problems: lines and artefacts
Start free trial →
8Collimator error on the forearm program only — diagnosis and repair
Start free trial →
9Replace the collimator assembly: removal, alignment and revalidation
Start free trial →
10The MAX board: tube current control and filament drive
Start free trial →
11Arcing in the x-ray tube head
Start free trial →
12Replace the x-ray tube head
Start free trial →
13The XORB board — transient protection and the high voltage test points
Start free trial →
14Communications failures
Start free trial →
15Indicator failures: lamps and LEDs
Start free trial →
16The Laser board: five components, and the mounting screw that kills the OINK
Start free trial →
17The software will not print but Windows will — DPX-IQ with a USB printer
Start free trial →
18Femur scan problems
Start free trial →
19\"Error Acquiring AP Spine\" with a data-file failure in the log
Start free trial →
20DIAGS test groups: limit switch, motor and x-ray
Start free trial →
21Open the DIAGS service software
Start free trial →
22Use the Static Counter (DIAGS)
Start free trial →
23Read the scanner error log with ERRDUMP
Start free trial →
24Diagnostic failure codes
Start free trial →
25A failing Quality Assurance test
Start free trial →
26Failing air matrix results
Start free trial →
27Run the Quick Collimation Ratio test
Start free trial →
28Run the daily QA with the calibration standard
Start free trial →
29Standard positioning problems
Start free trial →
30Viewing quality assurance trends
Start free trial →
31The SBC board — the I/O map of the whole machine, and the test points that read it
Start free trial →
32Start-up software problems
Start free trial →
33Electrical noise
Start free trial →
34Replace the lower cable bundle
Start free trial →
35Replace the tube head control cable
Start free trial →
36Mechanical failures: transverse, longitudinal and limit switches
Start free trial →
37The OINK board — the isolation way-point, the motion watchdog and the machine's failsafe
Start free trial →
38The OMI board — the machine's proof that the arm actually moved
Start free trial →
39Diagnose and correct slack in the transverse drive
Start free trial →

39 sections · Full content available after sign in

Frequently asked questions

Where can I access the GE Lunar DPX-IQ service manual?▾

The full DPX-IQ service manual is on FSELIB — the field-service engineering library for medical imaging. Sign in or start a 7-day free trial to open the complete manual: installation, calibration, troubleshooting, error codes and replacement procedures.

What does the DPX-IQ service manual cover?▾

It covers The AMP board: how the PMT pulse is built, and where to put the probe, Run the AGS test, and adjust only if it is justified, The AGS-05 board: signal path, test points and what TP12 is telling you, Air counts: unstable, none, or decreasing, Adjust the detector peak (HV ADJ - R43), The DCA board: how the scanner decides which photon it just saw and more for the GE Lunar DPX-IQ (Bone Densitometry).

Is the DPX-IQ service manual free to download?▾

Access is by subscription, with a 7-day free trial. FSELIB hosts authored, web-first service documentation (searchable procedures, diagrams and error-code references) — not a scraped PDF.

💬 Forum Discussions about this Model