GE X-ray R&F — field troubleshooting
3,432 field-service issues · page 11 of 43
Symptom, error message and equipment context for each GE X-ray R&F issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Definium 6000X-ray R&F
- The system cannot auto trackX-ray R&F · 1090419, 1090453
- Positioner will not move, error indicating movement detected during BISTX-ray R&F
- no 24v power for generatorX-ray R&F
- Generator error 040 on power up.X-ray R&F
- cpi generator report error "generator offline", can't exposure.:replaced the F3 and F4 on generator interface board.X-ray R&F
- Precision 500D error code 1100123 and 1100124 Failure to Setup Image Intensifier Optics with Debug text Neutral Density Filter Timeout during prep or after a digital record exposure.X-ray R&F · 1100124
- processed image distorted, image pixels are rotated 45 degrees (oblique orientation).X-ray R&F
- System turns off on it's own shortly after powering on.X-ray R&F
- Replace rotor board start capacitors - order rotor capacitor kit for MX100 , FRU = 2215674X-ray R&F · 3601144
- XRd, XQi Setting the clock is 12 hours off.X-ray R&F
- PROTEUS XRa - Blown F1 on KV CONTROL PCBX-ray R&F
- 180539 Definium 8000X-ray R&F
- What is the part number for the fiber optic loopback connectorX-ray R&F
- Optics control error 100123 or 100124X-ray R&F · 1100123, 1100124
- SYSTEM CAN'T POWER ON,WHEN SWITCH ON THE SYSTEM.X-ray R&F
- error 718, 720, replaced the rotor board and solve the problemX-ray R&F
- Preceision DXR-RXi error 037 when boot upX-ray R&F
- Replace brake cablesX-ray R&F
- AWS shuts down on it's ownX-ray R&F
- Definium6000_When system power on, Jedi generator inverter capacitor burned, AC/DC PCB F1 fuse (15A 700VDC) was brokenX-ray R&F · 3601222, 3601224
- Discovery XR650 AEC calibration is not same as the screen menu toldX-ray R&F
- Revolution XRd Digial Rad Error 6422 4932 on Advantx-E console.X-ray R&F
- Revolution XRd When selecting a procedure on the Advantx Console an Error 6423、6424 appeared on the consoleX-ray R&F
- Replace the 5128334 Motion Control Amplifier - NWKX-ray R&F · 1090252
- Proteus XRa Cannot exposure,Error 60-0313X-ray R&F
- 181596 Discovery XR650X-ray R&F
- Wallstand will not stay locked in vertical position, falls forward between 2 and 5 degrees.X-ray R&F
- Error 4162 Filament Drive ErrorX-ray R&F
- Generator error 3601238X-ray R&F · 3601238, 3601260
- unable exposure when press the handswitchX-ray R&F · 3601203, 3601195
- What are the Magic PC HP 8200 workstation BIOS settingsX-ray R&F
- AMX 4 - Error 462 Generator FaultX-ray R&F
- Compression locks not working, lock indicator stays illuminated all the timeX-ray R&F
- digital rad exposure disabled when FOV changed.X-ray R&F
- XRAPPS What are the patient weight limits for the various XRay tables?X-ray R&F
- WS hand control is crackedX-ray R&F
- AMX 4 - Broken Drive HandleX-ray R&F
- Prestige II Table drives slowly.Error code was PW18 or C17E0.X-ray R&F
- Prestige II can not fluoro because tube too hotX-ray R&F
- After replace magicPC mainboard,The system needs to press F1 to boot and displays Invalid electronic serial numberX-ray R&F
- The wallstand detector can not make exposure when insert the 180cm grid,the message says QAP phantom is inserted,remove it and continueX-ray R&F
- Definium 8000 exposer inhibitX-ray R&F · 3601238
- when the table tilted to vertical 90 degree, tube arm can not move up with error 0470,04d9X-ray R&F
- XT locks are not workingX-ray R&F
- Can not use the 180cm wallstand grid to make exposure,it displays the message "QAP phantom is inserted,remove it and continue"X-ray R&F
- remote control signal can not be recognized by infrared receiverX-ray R&F
- XRd2X, Def8000, AMX700 Need to be able to query the network nodes for speed and modes.X-ray R&F
- Unable to make an exposure with the table detector connected to the rear port on the table.X-ray R&F · 1220706
- Release (reset) the emergency push button - NWKX-ray R&F
- Error 50-0204 Filament permanent open circuitX-ray R&F · 500211
- Definium8000 tracking errorX-ray R&F
- the Prestige II intermittently can't do the exposalX-ray R&F
- PII DRS no respond,can't creat new patient,patient directory is not availableX-ray R&F
- Fe needs to do Load from Cold but cannot access the splash screen to select boot from CDX-ray R&F
- Definium 8000X-ray R&F
- NETWORK CONNECTOR NEEDS REPLACEMENTX-ray R&F
- Collimator lamp not workingX-ray R&F
- Error 718,720 or 720 occurred when x-ray activatedX-ray R&F
- VIC - Light Bias Error 4727X-ray R&F
- PROTEUS Collimator light bulb burned out.X-ray R&F
- GENERATOR ERROR 60-0313 / 3 ILR MAX CURRENT DETECTED / EXPOSURE STOPPED RELEASE EXPOSUREX-ray R&F
- SYSTEM TIME IS INVALID MAY NEED TO REPLACE ONBOARD BATTERYX-ray R&F
- OTS UIF handle brokenX-ray R&F
- The HP8200 computer will halted during working intermittentlyX-ray R&F
- E stop message on consoleX-ray R&F · 5800012
- GPX Prestige II Error Message E8004X-ray R&F
- No exposure - error 6405X-ray R&F
- Definium8000 Move the Wallstand receptor away from the hard limit and reset. - QRPOX-ray R&F · 1090453
- Virtual collimation is not working on IDDX-ray R&F · 6400005
- collimator led is not onX-ray R&F
- system can not exposerX-ray R&F
- PII cannot boot up, DRS Black screen with ‘beep’X-ray R&F
- error 320:Replacement of DC Filter board and/or CT2X-ray R&F
- AMX4+X-ray R&F
- Amx4 can not drive forwardX-ray R&F
- The operating system hangs during boot up or reset and asks the user to complete a FSCK.X-ray R&F
- Definium AMX 700 The operating system may hang during boot and ask the user to complete an FSCK (File System Check).X-ray R&F
- Ultranet collimator lamp is burned outX-ray R&F
- error 467 do the taps cal in generator calX-ray R&F