GE Healthcare · CTLightSpeedVCT23001501624520123001500524521511000

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 230015016 Failure reading cal file information from cal file. File name then listed See Long Description for examples. Wed Jan 18 13:09:37 2006 Error: 230015016 Host: cmh_ct_ls1 Process: scanmgr File: cal_db_api.c Line: 1326 Function: CAL Processing : SBC Processing Failure reading cal file information from cal file. File: /usr/g/cal_db/tracking/misc/tracking_constants Sun Sep 24 15:33:17 2006 Error: 230015016 Host: wvct Process: scanmgr File: cal_db_api.c Line: 1326 Function: CAL Processing : SBC Processing Failure reading cal file information from cal file. File: /usr/g/cal_db/tracking/das_gain/das_gain Wed Feb 20 16:26:01 2008 Error: 230015016 Host: bay44 Process: scanmgr File: cal_db_api.c Line: 1812 Function: CAL Processing : SBC Processing Failure reading cal file information from cal file. File: /usr/g/cal_db/tracking/coll_cal/8x0625/small_spot/collimator_cal

Error: 245201 The current scan has been aborted due to an invalid tracking calibration See Long Description for details Wed Feb 20 16:26:01 2008 Error: 245201 Host: bay44 Process: scanmgr File: scanmgr_lib.cxx Line: 682 The current scan has been aborted due to an invalid tracking calibration

Error: 230015005 Un

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.