GE Healthcare · CTLightSpeedVCT18221527309170900
Cradle Drive Motion was prohibited by hardware Interference switches
Symptom
Cradle Drive Motion was prohibited by hardware Interference switches
Error message
Error: 182215 Motion was prohibited by hardware interferenceHardware Inhibit Switches 0x80fc. Mon Sep 27 20:29:03 2004Error: 182215 Host: ETC Process: Cradle File: cmcStart.c 1.60 7/23/96 7/23/96 Line: 404 Function: PATIENT ANATOMY POSITIONING : Cradle Drive Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 20:29:03:355 Log Series: 32 HW/SW error: Motion was prohibited by hardware Interference switches. Hardware Inhibit Switches 0x80fc Current Position 27309 (.01 mm) Dir: 1 (0 = Out 1 = In [Gantry]) Positions 0 (.01 mm) 170900 (.01 mm) Mon Sep 27 20:29:03 2004 Error: 182215 Host: ETC Process: Cradle File: cmcStart.c 1.60 7/23/96 Line: 404 Function: PATIENT ANATOMY POSITIONING : Cradle Drive Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 20:29:03:355 Log Series: 32 HW/SW error: Motion was prohibited by hardware Interference switches. Hardware Inhibit Switches 0x80fc Current Position 27309 (.01 mm) Dir: 1 (0 = Out 1 = In [Gantry]) Interference Positions 0 (.01 mm) 170900 (.01 mm)
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 1.X - GRE H1_P_S4 Lightspeed 1.X - GRE Method of visual identification Large square gantry similar in appearance to a CTi gantry. Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required