GE Healthcare · CTHiSpeed186218

Scanner Hardware Stopped Scan

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 186218 Exposure error : Spit Ratio error detail error code : 60 - 0317H Tue Aug 24 18:26:30 2004 Error: 186218 Host: IRIS Process: tgp_out File: tgp_in_input.c Line: 334 XG Error Exposure error : Spit Ratio error detail error code : 60 - 0317H phase is 5 code is 60.

Error: 186218 Exposure error: 60 - 0316H Spit Max error detail error code Error: 186218 Exposure error : Spit Max error detail error code : 60 - 0316H The error 186218 could mean many things. The error that needs to be focused on is the detail error code : 60 - 0316H. In the YMS error code list it states the following.. Error code: (*) for NP 60-0316H Message/explanation: Spit Max error. kV control has detected the number of tube spits during exposure has reached the limit (see theory of operation, software section) Potential cause: reasonably x-ray tube Recommended action/Troubleshooting guide: 1 Try again at various kV/mA to confine problem. 2 If it is associated to kV regul out spit detection, check mains input voltage connection 3 Troubleshoot HV section. (x-ray tube, cable, HV tank) 4 Diagnose based on tube history

Applies to

Models
HiSpeed
Product
HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
Component
D3141T / D3142T STANDARD tube Used In Highspeed NXi/Fxi/Lxi/Dxi/Np ( This is not a PERFORMIX tube ) D3142T x-ray tube STANDARD tube Used In highspeed NXi/Fxi/Lxi/Dxi/Np ( This is not a PERFORMIX tube D3152T )
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required