Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT260132914

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Attention The detector is not at the proper temperature. see long description for more detail. Attention The detector is not at the proper temperature. If you wish to proceed with this scan select the "OK" button, however IQ may be degraded including image artifacts. Please contact GE Service

Error message

Error: 260132914 Rail Temperature Out Of Range See Long Description for complete error Temperatures vary. Wed Jun 21 14:51:53 2006 Error: 260132914 Host: orp Process: orp_subsys File: ThermalManager.cxx Line: 2071 Wed Jun 21 14:51:52 2006 Host : Das Ermes # : 260132914 Exception Class : Secondary Severity : Sec/Soft File : ThermalManager.cxx Line# : 2071 Function : No System Function Reported Scan Type : None/Unknown Scan: 81/201/0 Rail Temperature Out Of Range Sensor: Rail Low Channel Temperature: 3640 <--- In this case, temp was always too LOW Average A/D Temperature: 0 Limits: 3650, 3950

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5129997 VCT RAIL THERMISTOR SERVICE KIT Contains all 3 sensors and attachment tape for wiring See LD for details Part #: 5129997 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT Rail Thermistor Service Kit FRU: Yes Status: Orderable Comments: Added 2/25/05 (212001261) VCT Top Critical Part is returnable, please return per RMA assigned when you order this part
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues