Scanner Software would not allow protocols to be edited or used

Symptom

Scanner Software would not allow protocols to be edited or used Scanner Software would not allow protocols from savestate to be edited or used. After a failed image data disk was replaced and software reloaded, tech could not edit protocls that were restored from system state MOD nor could scan with them

Error message

Error: 200109072 The unknown series-level field "isAutoFilmDoseEnabled" was encountered in a protocol file. See the LD for the complete error Mon Jul 17 10:24:12 2006 Error: 200109072 Host: rcamdct1 Process: scanRx File: Series.cxx Line: 109 The unknown series-level field "isAutoFilmDoseEnabled" was encountered in a protocol file.

Applies to

Models
LightSpeed
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5136941 SmarTube Phase 2 SW Patch for Irix/Pegasus Systems 5136941 SmarTube Phase 2 SW Patch for Irix/Pegasus Systems 5136941 SmarTube Phase 2 SW Patch for Irix/Pegasus Systems Below are the items included in kit 5136941 Qty Description Part # 1 FMI 25363 Document 5142331-100 1 LS2002M5 software Patch G.6 5142334 1 Tips and Workarounds 5115418-100 1 Customer Letter 5142333-147 Part #: 5136941 Part Type: GP FMI Part Weight: 2.43 LBR Repairable: No Returnable: No Hazardous Material: N Description: FMI 25363, Smart Tube Phase 2, Software Patch for IRIX Pegasus FRU: Yes Status: Orderable ICV/Transfer Price: 0.00 USD /Each List Price: 229.00 USD /EACH
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.