Infinia Querying the studies from a HIS/RIS server (MWL) returns no entries, although all the MWL settings hav…
Infinia Querying the studies from a HIS/RIS server (MWL) returns no entries, although all the MWL settings have been correctly configured
Symptom
Infinia Querying the studies from a HIS/RIS server (MWL) returns no entries, although all the MWL settings have been correctly configured Infinia Querying the studies from a HIS/RIS server (MWL) returns no entries, although all the MWL settings have been correctly configured. Modality Worklist (MWL) query returns no entries due to DICOM tag [Reason for Study] (0032,1030) containing more than 64 characters - PQRs 13087532 and 13143771
Error message
MC_Get_Value_To_String failed Value too large for buffer ERROR=Error in NetworkServer d:\tacq\cu\src\cxx\dm\nw2\mergeobj.cpp(72)::MC_Get_Value_To_String failed Value too large for buffer The following error is logged in the NetworkServer log (D:\tacqdb\log\[email protected]): ERROR=Error in NetworkServer d:\tacq\cu\src\cxx\dm\nw2\mergeobj.cpp(72):: MC_Get_Value_To_String failed Value too large for buffer buildWorkListLevelResponseList:: couldn't get value for tag 4199424 WARNING=Warning in NetworkServer d:\tacq\cu\src\cxx\dm\nw2\dicomserviceuser.cpp(1425) buildWorkListLevelResponseList:: couldn't get value for tag 4199424 The following warning is logged in the NetworkServer log (D:\tacqdb\log\[email protected]): WARNING=Warning in NetworkServer d:\tacq\cu\src\cxx\dm\nw2\dicomserviceuser.cpp(1425) buildWorkListLevelResponseList:: couldn't get value for tag 4199424 NOTE: The DICOM tag in this warning message is displayed as a decimal value. DICOM tags are typically displayed as hexadecimal values. It is necessary to convert the decimal value to hexadecimal to properly interpret the DICOM tag that is causing the issue. In this case decimal 4199424 converts to hexa
Applies to
- Models
- Infinia
- Product
- Infinia I Infinia I Acquisition System
- Software
- Infinia 1.004.009.21 Infinia M4 version is 1.004.009.21 Infinia M4 version is 1.004.009.21
- Component
- *Software Software Software
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.