GE Healthcare · CT260118162

CT/e, CT Prospeed AI/FI Irix or Linux

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260118162 (30-0324) Tube spit (all kV dropped errors). See LD for error explanation Code 30 Tube Spits Detection Errors 305 324 data=1 324 data=2 324 data=4 324 data=8 328 Error code: 30-0324H Data = 1 (see note) Code 30 Message/explanation: Tube spit (kV+ has dropped) kV drop/spit detected on Anode side Potential cause: Anode side Tube spit. Anode HV cable HV tank Recommended action/ Troubleshooting guide: If too frequent: Check HV cables and contacts in tube and generator sides (no black traces, grease or oil in them except on HV cable equipped with a mini connector for vascular tube) Remove HV in generator side, fill HV receptacles with oil and run Open load kV test. (See diagnostic section). If test fails, replace HV tank. Swap and connect HV cables. Run Open load kV test. (See diagnostic section) If test fails, replace anode HV cable. Otherwise, tube problem (Anode side). Refer to x-ray tube maintenance manual or replace tube. Error code: 30-0324H Data = 2 (see note) Code 30 Message/explanation: Tube spit (kV- has dropped) kV drop/spit detected on cathode side Potential cause: Cathode side Tube spit. Cathode HV cable HV tank Recommended action/ Troubleshooting guide: If

Applies to

Product
CT/e, CT Prospeed AI/FI Irix or Linux See long description for sale information Product Name: CT/e Single CT Scanner: Irix Platform A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) 3.01 / 3.02 / 3.03 Linux CTe Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found in the attachment Always use the most appropriate documentation for your system.
Component
D3161T / D3162T Venus tube used on CTE (D3161T is NEW non reload version) See Long Description for details X-ray tube D3162T / D3161T , Modified Venus tube Part #: D3162T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX135 CT TH.1.1 RELOAD FRU: Yes Status: Orderable Comments: FLS - ECONOMY SLIP RING CT TUBE (ALSO CALLED CTE HIGHSPEED) 23 OHM (STATOR RESISTOR VALUE) 11/24/99 AM SOURCE = MEXICO FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA Part #: D3161T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX135 CT TH.1.1 GREEN FRU: Yes Status: Orderable Comments: This is GREEN tube, order only if New is required , If not please SEE D3162T, ms13452
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues