GE Healthcare · CTHiSpeed18341714272

HiSpeed CTi 6.X with Octane and HSA Gantry

Symptom

"Scan hardware Stopped Scan" with collimator errors. "Scan hardware Stopped Scan" with collimator errors

Error message

Error: 183417 Filter did NOT find the Z Pulse position in time See LD for full error Error: 183417 Filter did NOT find the Z Pulse position in time Mon Nov 25 08:11:57 1996 Error: 183417 Suite: CT01 Host: OBC Proc: Collimator File: move filter.c 1.13 6/24/9 Method: No Method Line: 109 Function: XRAY GENERATION : Xray Collimation and Filtration Scan: 14272/1/1 Type: Scout Exception Level: Pri/Most Severe Time: 08:11:57:395 Log Series: 201 Filter did NOT find the Z Pulse position in time. (No Hardware Interrupt) Time allowed = 5000 msec.

Applies to

Models
HiSpeed
Product
HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-296300G4 and 46-296300G5 EMC COLLIMATOR -used on CTi and compatible to HSA See LD for more info 46-296300G4 and 46-296300G5 EMC COLLIMATOR -used on CTi and compatible to HSA picture 46-296300G4 EMC COLLIMATOR Part #: 46-296300G4 Part Type: GP REPAIRABLES Part Weight: 19.54 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: 860-950117 EMC COLLIMATOR FRU: Yes Status: Orderable Comments: FLS - FE: READ SERVICE NOTE T-1379 5/96 GVR T3202GR MPS INFO: B7999KK CONTAINS G4 COLLIMATOR PLUS S/W. MFG PLANIS TO DEINSTALL THE G3, HAVE FE RETURN, UPGRADE, AND USE INADDITIONAL KITS PER R. KOPP. 10/95 FLS - FE ASSIST MS6588 5/2000 46-296300G4 = GRAPHITE FILTER COLLIMATOR. IF NO STOCK IS AVAILABLE ORDER 46-296300G5. THE G5 COLLIMATOR IS COMPATIBLE ON CTI HSARP AND HSAZ SERIES SYSTEMS. DO YOU STILL WANT TO ORDER THIS PART??? Part #: 46-296300G5 Part Type: GP REPAIRABLES Part Weight: 19.09 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: EMC COLLIMATOR FRU: Yes Status: Orderable Comments: FLS - COST REDUCED EMC COLLIMATOR USED ON FAST RHAPSODE 7/2/97 GWENN 08992 T3202KM 11/19/02 -BUILD OUTSOURCED FRMCT MFG TO ERDA PER GINA DUNDUNM KRAETSCH. MS12464 FLS - FE ASSIST MS6588 5/2000 T3202KM = G5 COLLIMATOR COST REDUCED EMC COLLIMATOR USED ONHSARP, HSA AND CTI SYSTEMS. THE G5 (T3202KM) WILL NOT WORKON HELIOS/LIGHTSPEED SCANNERS. DO YOU STILL WANT TO ORDER THIS PART???
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.