GE Healthcare · CTLightSpeed18288322298712256730
LightSpeed 3.X (Ultra, Plus, QX/i) - Octanex
Symptom
Gantry display shows ERR and fails firmware flash download. See long description
Error message
Error: 182883 An Invalid RESET has been Detected. Node Type: TNC (ETC I/F). See Long Description for more details Mon May 9 13:45:23 2005 Error: 182883 ETC Gantry Display gd tnc erlog.c 611 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 13:45:23:085 Log Series: 39 An Invalid RESET has been Detected. NOTE: Reset Reason of 0x60 is Expected after FLASH Download. Reset Reason: 0x10. Node Id: 0 Node Type: TNC (ETC I/F). Board Number: 2229871 Serial Number: 0. OR Error: 182883 Host: ETC Process: Gantry Display File: gd_tnc_erlog.c Line: 611 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 21:24:30:390 Log Series: 10 An Invalid RESET has been Detected. NOTE: Reset Reason of 0x60 is Expected after FLASH Download. Reset Reason: 0xe2. Node Id: 1 Node Type: GANTRY DISPLAY. Board Number: 2256730 Serial Number: 7596.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2372485 ETC IF (Interface or TNC Bd.) Replaces 2229871 See long description for details 2372485 ETC IF (Interface or TNC Bd.) Replaces 2229871 Part #: 2372485 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: ETC INTERFACE W/ AZ60A FRU: Yes Status: Orderable Comments: FLS - ETC INTERFACE W/ AZ60A. ADDED PER PCN 220857. REPLACES P/N 2229871. USE UP EXISTING STK. MS20544 5/1/03. ONE USE LIGHTSPEED PLUS VC:611695-SCI, RAPID CITY, SD CONTROL PCB 46-264368G3
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.