Gantry Control Panel not working.

Symptom

Gantry Control Panel not working. Long Description for Feedback Only. Gantry Control Panel not working.

Error message

Error: 182418 Elevation Pushbutton select timeout detected by hardware. See LD for full Error Error: 182418 Elevation Pushbutton select timeout detected by hardware. Fri Dec 16 09:17:56 2005 Error: 182418 Host: ETC Process: Elevation File: emcControl.c 1.23 11/13/92 Line: 225 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 50515/11/0 Type: None/Unknown Exception Level: Pri/Soft Time: 09:17:56:955 Log Series: 963 HW/SW error: Elevation Pushbutton select timeout detected by hardware. Current Position 1189 (.1 mm). Elev Direction: 1 (0 = Up 1 = Down).

Error: 260111021 GUIF CAN node response timeout See LD for details Wed Apr 4 16:55:13 2007 Error: 260111021 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 1453 Wed Apr 4 16:55:13 2007 Host : Table Gantry Processor Ermes # : 260111021 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 1453 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : None/Unknown Scan: 9106/1/0 GUIF CAN node response timeout. Node part number 2256730. Node serial number 32636. Node CAN ID# 1.

Applies to

Models
BrightSpeed
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5168106 SL4 Reduced Force TGC Assembly - RIGHT Side Gantry Control Panel See long description 5168106 SL4 Reduced Force TGC Asm - RIGHT Side Gantry Control Panel Part #: 5168106 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: SL4 reduced-force TGC Assembly, Right Side FRU: Yes Status: Orderable Comments: added per to BrightSpeed RSPL
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.