GE Healthcare · CTHiSpeed00000
HiSpeed CTi 6.X with Octane and HSA Gantry
Symptom
Octane computer will not boot with gfx graphic board #1 error in the SYSLOG Octane computer will not boot with gfx graphic board #1 error in the SYSLOG. Both monitors go blank
Error message
Graphics error :scti unix: gfx board #1 Graphics error Sep 20 06:38:10 2A:scti unix: gfx board #1 Sep 20 06:38:10 2A:scti unix: irnode(0000002073a1c8 Sep 20 06:38:10 2A:scti unix: gfxp(0000002df44ea0, pid7, boundrn(000000203bcca0 , rnodep(0000002bd10600 Sep 20 06:38:10 2A:scti unix: gfxp(00000020d23660, pid7, boundrn(000000203bcd48 , rnodep(0000002fdc1e00 Graphics error Sep 20 06:38:10 2A:scti unix: gfx board #1 Sep 20 06:38:10 2A:scti unix: irnode¨0000002073a1c8 Sep 20 06:38:10 2A:scti unix: gfxp¨0000002df44ea0, pid7, boundrn¨000000203bcca0 , rnodep¨0000002bd10600 Sep 20 06:38:10 2A:scti unix: gfxp¨00000020d23660, pid7, boundrn¨000000203bcd48 , rnodep¨0000002fdc1e00 Sep 20 06:38:10 2A:scti unix: gfxp¨00000027ae8840, pid 55, boundrn=0, gfxp¨00000 02066a8e0, pid 59, boundrn=0, active rnode¨0000002bd10600
Applies to
- Models
- HiSpeed
- Product
- HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2169940-36 replaces 2169940-3 Card 1 or 2 Graphics board used in the Octane computer part number 2169940-3 Card 1 or 2 Graphics board used in the Octane computer 2169940-36 replaces 2169940-3 Card 1 or 2 Graphics board used in the Octane computer Part #: 2169940-36 Part Type: GP REPAIRABLES Part Weight: 1.09 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: DUAL HEAD SE GRAPHICS OPTION/SPARE FRU: Yes Status: Orderable Comments: FLS - DUAL HEAD SE GRAPHICS OPTION /SPARE. U/O HELIOS & CTI 225MHZCOMPUTER. 1/22/99 MS08992. T3 CANDIDATE 2001. EOL QTR4 2001PCN 199401 2169940-36 REPLACES2169940-3. CANNOT ORDER MORE FROM SGI (PER JOHN MAYERS) SO SSS BLOCKED. HQT HISTORY: NEWEST TO OLDEST 030-1241-002 HU-DHSE GELS - THE -36 IS THE DUAL HEAD ON THE NEW OCTANE (225) FP 99/05,DUAL HEAD SOLD IMPACT GRAPHICS Part #: 2169940-3 Part Type: GP REPAIRABLES Part Weight: 1.81 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: OPTION DUAL HEAD GRAPHICS FRU: Yes Status: Orderable Comments: FLS - OPTION DUAL HEAD GRAPHICS USED ON NEXGEN COMPUTER MS08992 6/8/97 T3202KH PART HAS GONE END OF LIFE CONVERTING TO EXCHANGE. OUTRIGHT SALES MS08992 11/16/98 GWENN 199401 2169940-3 REPLACED BY 2169940-36 9/99 MS08992 2169940-3UA=J & M TRADING GELS - THE -3 HAS GONE END OF LIFE AND IS USED ON OLDER OCTANE 2169940-36 CAN BE DELIVERED INSTEAD. WAITING M.MEIER ABOUT THE LINKANBAN CSS F00 030825 IS REPLACED BY 2169940-36 ROUILES,DUAL HEAD
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required