LightSpeed 4.X - Octane

Symptom

CTx00088 Proactive svc call by PDS See long description for details CTx00088 Proactive svc call by PDS This Issue was detected by the Digital Services (DS) rule engine. This Issue is only applicable when detected by the Rules Engine and should not be reused in Knowlege objects for normal reactive service

Error message

Error: 183327 HEMRC fault detected. Long Description contains complete error. Mon Jul 24 08:41:32 2006 Error: 183327 Host: OBC Process: Generator File: gen_abort.c 1.31 Line: 625 Function: XRAY GENERATION : Tube Rotor Control Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 08:41:28:555 Log Series: 31 HEMRC fault detected. See system log for additional error information. Fault latch address = ffb82b hex, Bit = D0

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - Octane sw_version: 405I.2_H4.0M5 LightSpeed 4.X - Octane Gantry Model # 2339985 Console Model #'s 2341923 and 2341923-2(D3D) check_config shows LightSpeed 16 / LightSpeed 16 Product: LightSpeed16 sw_version: 405I.2_H4.0M5 or newer machine_type: Octane host_id: 3232297858 tube_type: 15 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2203602 (replaces 2161307) HEMIT HV TANK used on CT/I (performix), HiSpeed QXi, LS1.X LS2.X, LS 3.X, LS4.X See Long Description for details Part #: 2203602 Part Type: GP REPAIRABLES Part Weight: 55.12 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: HEMIT HV TANK SPARE PART FRU FRU: Yes Status: Orderable Comments: ** FE ASSIST ** The HV adapter/Spacer part number 2171866 Kit that is included with the HV tanks But it is only used on older Highspeed Gantry due to the smaller bolt size. Refer to MI&CT ESERVICE NOTE SN07091114a for additional details. (212001261 21-Jan-2009) *** 2ND OPINION NOTES *** Take an exposure and listen to tank. If you hear an arcing sound most likely bad tank. Rotate Gantry so tank is upside down and take exposure. Listen for arcing. Turn off lights in room and check for a flash from the tank. Remove tank, set on floor on top of the lifting bracket. Make room quiet. Rock tank front to back and side to side, listen carefully. Any sounds, indicates a failure. Check tank for oil leaks Old FRU Compatible No Comments ct/i helio rspl Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable Yes Use on Hands No Use Demand History Yes Ultimate Prime 2203602 New FRU Backward Compatible Yes Old FRU Usable No Change Type Direct ECO Number 9999
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.