GE Healthcare · CTLightSpeed26011102122567303263626011100311569

Gantry Control Pad Flashing "err"

Symptom

Gantry Control Panel Flashing "ERR". Gantry Control Panel Flashing "ERR"

Error message

Error: 260111021 GUIF CAN node response timeout See LD for details Wed Apr 4 16:55:13 2007 Error: 260111021 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 1453 Wed Apr 4 16:55:13 2007 Host : Table Gantry Processor Ermes # : 260111021 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 1453 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : None/Unknown Scan: 9106/1/0 GUIF CAN node response timeout. Node part number 2256730. Node serial number 32636. Node CAN ID# 1.

Error: 260111003 GUIF CAN bus error status returned. See LD for Full Error Error: 260111003 GUIF CAN bus error status returned. Fri Jan 21 10:30:39 2005 Error: 260111003 Host: tgp Process: tgp_subsys File: guif_can_mgr.c Line: 490 Fri Jan 21 10:30:38 2005 Host : Table Gantry Processor Ermes # : 260111003 Exception Class : Soft Severity : Sec/Soft File : guif_can_mgr.c Line# : 490 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : Helical Scan: 11569/2/2 GUIF CAN bus error status returned. Error status 0x3.

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5139590 Control assembly left side gantry. ( replaces part# 2256729 and 2330695 ) – used on H2 & HP gantry’s (LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x ) FEMC info in Long Description. 5139590 Control assembly left side gantry. ( replaces part# 2256729 and 2330695 ) – used on H2 gantry’s (LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x ) Part #: 5139590 Part Type: GP CONSUMABLES Part Weight: 4.41 LBR Repairable: No Returnable: No Hazardous Material: N Description: H POWER OPERATOR CONTROLS LEFT SIDE FRU: Yes Status: Orderable If part number 2330695 is ordered it will automaticaly cross to part 5139590 Old part info 2256729 Control assembly left gantry Part #: 2256729 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: CONTROL ASM LEFT H2 GANTRY FRU: Yes Status: Orderable 5139591 control assembly right side gantry ( replaces part# 2256728 and 2330703 ) ) – used on LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x (HD uses a different control panel) See Long Description. 5139591 control assembly right side gantry ( replaces part# 2256728 and 2330703 ) ) – used on H2 gantry,s (LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x ) Part #: 5139591 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: H POWER OPERATOR CONTROLS RIGHT SIDE FRU: Yes Status: Orderable OLD part info 2256728 control assembly right gantry Part #: 2256728 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: CONTROL ASM RIGHT H2 GANTRY FRU: Yes Status: Orderable Comments: If no stock is available, order 5139591 per ECR 2025944; 6/20/2006 MS11892 FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA Part #: 2330703 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: H POWER OPERATOR CONTROLS RIGHT SIDE FRU: Yes Status: Orderable Parts Offered as: Current: 2330703 Harvested: Not Available Exchange: Not Available Comments: If no stock is available, order 5139591 per ECR 2025944; 6/20/2006 MS11892. 212012201 02/09/2007 19:34 GMT
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required