Pular para o conteúdo principal
GE Healthcare · CTHiSpeed

Intermittently, system freezes up in the middle of displaying images.

Symptom

Intermittently, system freezes up in the middle of displaying images. Long Description for Feedback Only. Intermittently, system freezes up in the middle of displaying images.

Error message

FIC1 unix: ALERT: SCSI command on (1,4) timed out See Long Description for complete error. 1.- Thru Insite, log on to system, enter the ezlog, and choose the /usr/adm/SYSLOG for analysis. ( You can do the same in an unix window...with more /usr/adm/SYSLOG ) SYSLOG is where IRIX hardware and operating system software errors are reported. Here You will find the reason for CPU malfunction, SCSI Errors and indications of system Start ups. In this particular case, this is what was found: May 8 06:36:23 1A:FIC1 unix: ALERT: SCSI bus reset on controller 1. May 8 06:36:25 5A:FIC1 unix: NOTICE: recvcomp: stat=0x7,scsistat=0x0 May 8 06:36:25 2A:FIC1 unix: May 8 06:36:40 1A: FIC1 unix: ALERT: SCSI command on (1,4) timed out after 7 ss. SCSI (1,4) is the Serial port expander, ST1800.

Applies to

Models
HiSpeed
Product
HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
Component
2280219(for HiSpeed) or 2280220(for CT/e) Serial Expander Replacement Kit replaces (2243265 ST1800 Serial Expander Card) See Long Description for Details. ST1800 is no longer available. There is a replacement kit for it. Serial Expander Replacement Kit (for HiSpeed Series): P# 2280219 Part #: 2280219 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: P9231RQ SERIAL EXP.REPLACEMENT KIT_F FRU: Yes Status: Orderable ICV/Transfer Price: 1341.62 USD /Each List Price: 0.00 USD /EACH Comments: FLS - SERIAL EXPANDER REPLACEMENT KIT TO BE USED IN OPERATOR CONSOLE OF HISPEED LX/I, FX/I, DX/I, AND DX/I MOBILE. ADDED PER SERVICE REQUEST (ASIA). ASIA SPCN# CT-1767NP-5. MS20544 ON 4/8/02. Part #: 2243265 Part Type: GP CONSUMABLES Part Weight: 2.01 LBR Repairable: No Returnable: No Hazardous Material: N Description: P2001VA SERIAL EXPANDER CARD FRU: Yes Status: Orderable ICV/Transfer Price: 880.81 USD /Each List Price: 4178.00 USD /EACH Parts Offered as: Current: 2243265 Comments: FLS - SERIAL EXPANDER CARD U/O EBISU (NPI) MS08992 6/5/00
Area
CT