GE Healthcare · CTLightSpeedVCT26011821410132
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Fault with high voltage spits. Scanner Hardware Fault with high voltage spits
Error message
Error: 260118214 (60-0317) Spit Ratio error See Long Description for complete error. Fri Dec 16 23:26:55 2005 Error: 260118214 Host: orp Process: orp_subsys File: gen_exec.c Line: 2150 Fri Dec 16 23:26:54 2005 Host : Jedi Ermes # : 260118214 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2150 Function : No System Function Reported Scan Type : Axial Scan: 10132/2/1 (60-0317)Spit Ratio error. PPC board has detected the rate of tube spits during exposure has reached the limit (see theory of operation, software section).^C Z6,Z7= 4h,0h
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- D3194T PERFORMIX PRO-100 TUBE UNIT - Monopolar Hercules Tube used on 5.X (80/100), LS RT16, 7.X See Long Description for Details D3194T PERFORMIX PRO-100/VCT, RT16 and RT16 Xtra TUBE UNIT - Monopolar Hercules Tube used on 5.X (80/100), LS 5.X RT16, 7.X Part #: D3194T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERFORMIX PRO100/VCT (RG) & RT16 Systems FRU: Yes Status: Orderable Comments: Added per VCT RSPL, ms13452 041216 Comments: Added per VCT RSPL, ms13452 041216 FE ASSIST MSxxxx August 2005 D3194T = VCT / PRO 100 TUBE. VCT 32 or VCT 64 7.x systems may ONLY use D3194T tubes. 5.x HP 100 and HP80 Gdas systems may use either D3192T or D3194T tubes. '*** 2ND OPINION NOTES *** Perform Rotor Control Diagnostics--If tube rotor fails to reach RUN mode in three ACCEL steps look for: High Drive output currents Low Drive output voltages and Low Drive output frequencies. This indicates a load problem with tube. With rotor running turn off Gantry 120V power at PDU. Listen for excessive noise and short deceleration time. A good rotor will coast for several minutes without power. NOTE TO FES AND DCOS TEAM: IF SELLING TO AN END USER AND NOT INSTALLED BY A GE FE, AN END USER CERTIFICATION LETTER MUST BE SIGNED BY THE CUSTOMER. UPON RECEIPT OF SIGNED LETTER, ORDER CAN BE PLACED. **TO OBTAIN COPY OF CERT. LTR. CONTACT DCOS TEAM AT 800-558-2040 OPTION 2. **ANY QUESTIONS, CONTACT LYNN WESTBROOK OR ROD MCCRIMMON. ******* NOTE: D3194T tubes now manufactured, have a one inch longer high voltage cable. The longer cable is necessary for all Wide Bore Gantries. ( If a very old D3194T tube is installed on a Wide Bore Gantry, the high voltage cable may be too short, and a new D3194T tube must be ordered ).
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required