Intermittent Scan Abort, No laser lights with Axial errors

Symptom

Intermittent Scan Abort, No laser lights with Axial Errors. See LD for more details Intermittent Scan Abort, No laser lights with Error: 183911 Axial HOME value TIMEOUT Fault Error: 183946 Axial Encoder Feedback Error Error: 184181 Number of offsets acquired does not match estimate of number of offsets generated Error: 183921 183944 Intermittent Scan Abort errors. Intermittently when laser light button is pushed the gantry spins but the lights never come on. Error: 183911 Axial HOME value TIMEOUT Fault. HW/SW Error: Retry Rx to verify probable gantry hardware problem. Error: 183921 Axial conditions at FAULT Error: 184181 Number of offsets acquired does not match estimate of number of offsets generated HW ERROR: Possible hardware problem. Offsets generated (estimate): -4904 Difference Between Generated and Acquired: 9810 Test Margin: 12 Triggers Error: 183944 Axial Encoder Feedback Error Encoder counts dropped during scan, may result in rotated images. Check images for proper orientation. Call Service. Error: 183946 Axial Encoder Feedback Error Accumulated counts measured since last re-reference were 33350 different than expected. (tolerance = 30 counts) Probable cause: faulty axial encoder Possible cause: faulty axial control board.

Error message

Error: 183921 Axial conditions at FAULT: See Long Description for complete error Mon Oct 17 08:26:48 2005 Error: 183921 Suite: SMCT Host: STC Process: Axial File: ax_error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 28848/2/1 Type: Helical Exception Level: Pri/Most Severe Time: 08:26:47:775 Log Series: 141 Axial conditions at FAULT: velocity_fb = 2662 position_fb = 50389 Formatted data: 8100 100 8 7 1 0 1 1 101 1 0 2662 -12655275 13081394 2741 2582 134 133 0x019e38

Error: 184181 Number of offsets acquired does not match estimate of number of offsets generated See Long Description for complete error Wed Nov 16 10:17:50 2005 Error: 184181 Suite: CT27 Host: STC Process: Scan Control File: scTrigSeqActions.c 1.68 Method: No Method Line: 480 Function: XRAY GENERATION : Scan Data Trigger Acquisition Scan: 41674/201/1 Type: Axial Exception Level: Pri/Most Severe Time: 10:17:49:830 Log Series: 755 Number of offsets acquired does not match estimate of number of offsets generated HW ERROR: Possible hardware problem. Offsets generated (estimate): -4904 Difference Between Generated and Acquired: 9810 Test Margin: 12 Triggers

Error: 183946 Axial Enc

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-296854P2 Encoder - used on HSA/CTi/1.X gantries as the Axial Encoder and on Zeus Tables as the Elevation Encoder. See Long Description for part details Part #: 46-296854P2 Part Type: GP CONSUMABLES Part Weight: 0.88 LBR Repairable: No Returnable: No Hazardous Material: N Description: ELEVATION ENCODER FRU: Yes Status: Orderable ICV/Transfer Price: 104.55 USD /Each List Price: 815.40 USD /EACH Comments: FLS - ADDED PER PCN 189960. MS4636 4/22/97 & PCN 184587 MS03330 ** FE ASSIST ** Axial encoder HSA/CTi/1.X mounts on Axial Motor. (212001261 8/5/08) Part #: 46-296854P2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Axial Encoder FRU: Yes Status: Orderable Parts Offered as: Current: 46-296854P2 Used: Not Available Exchange: Not Available Comments: FLS - ADDED PER PCN 189960. MS4636 4/22/97 & PCN 184587 MS03330 5/5/97 COLLECTION OF DEFECTIVES START7/23/01 MS5277 FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA FE ASSIST: IN ORDER TO INCREASE REVENUE GLOBAL PARTS HAS CREATED A PROGRAM TO HARVEST PARTS FROM RENEWABLE RESOURCES. THESE PARTS OFFER DIRECT SAVINGS TO THE BUSINESSAND THE FIELD. ORDER THE "U" PART IF AVAILABLE. IF NO "U" USED PARTS ARE AVAILABLE CARES WILL CHANGE THE ORDER TOA NEW PART.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.